PLC-Designer UDP Communication
Name of Protocol
PLC Designer UDP Communication
Purpose
This protocol is used to run the network scan and the communication between »PLC Designer« and Controller.
Ports
udp/1740 … 1743
Architecture
This communication is based on the UDP communication.
ISO/OSI Model
PLC Designer UDP Communication in the ISO/OSI Model
Scan Network
Scan Network
The »PLC Designer« is installed on a computer with an exemplary IP address of 192.168.5.4.This requests the network via UDP protocol on port 1743 and requests the broadcast IP address in the subnet on 92.168.5.255 on ports 1740, 1741, 1742, 1743 in sequence. Existing devices, in this example 192.168.5.99, will respond via port 1740 and thus expose themselves to the network scan.
Communication
After performing a network scan, you can access the controller online. Here we use the previously scanned UDP connection.
UDP Communication