Product description

Product identification

This documentation applies to the following components with their identification:

Name of product and product ID

Name of product

Product ID

v430 7in

V43AE70000000S

v430 10.1in

V43AEA0000000S

v430 15.6in

V43AEF0000000S

v450 7in

V45AP78000000S

v450 10.1in

V45APA8000000S

v450 15.6in

V45APF8000000S

v450 PoE-Injector

V4ZA0AP010000S

Location in the network

These components are located in the automation pyramid at the control level. Furthermore, they are located in the security zone "CAP-Machine" (Zones and Conduits).

A diagram of a plant

Description automatically generated

Location in the network

The components addressed here have one relevant interface:

  • Conduit: Industrial Ethernet

    The visualization products are operated on the machine's internal network. If these components are operated outside this network, the consideration of cyber security is the responsibility of the operator. A cyber security risk analysis is recommended here.

  • Conduit: USB
    The USB port (on board for the v430, can be realized via Y-cable for the v450) is only to be used for firmware updates and not for daily use. It is recommended to keep it deactivated.

Intended purpose

The intended use of these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.

  • These components mentioned here are professional equipment and may only be commissioned and decommissioned by specialists.

  • These components also require maintenance during their life cycle, which must be carried out by the operator.

  • Modifications to the firmware or hardware of the component are not permitted.

  • If these components are taken out of operation or disposed of, the instructions here in the documentation must be observed.

  • The USB stick used for a firmware update must be physically removed and not kept plugged in.

Intended environment

The intended environment for these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.

  • The visualization products are operated on the machine's internal network. If these components are operated outside this network, the consideration of cyber security is the responsibility of the operator. A cyber security risk analysis is recommended here.

  • The components are not operated directly on the open Internet, but must also be operated by the operator via protection systems such as firewall, IDS, IPS, ... be protected.

Security key indicators

Security key indicator (in accordance with IEC 62443-4-2):

  • These components are considered embedded devices (EDR).

  • These components have a security level of SL-C 0.

  • These components have an SL-vector from SL-C(v4x0)={ IAC=0; UC=0; SI=0; DC=0; RDF=0; TRE=0; RA=0 }