Product description
Product identification
This documentation applies to the following components with their identification:
Name of product and product ID
|
Name of product |
Product ID |
|---|---|
|
v430 7in |
V43AE70000000S |
|
v430 10.1in |
V43AEA0000000S |
|
v430 15.6in |
V43AEF0000000S |
|
v450 7in |
V45AP78000000S |
|
v450 10.1in |
V45APA8000000S |
|
v450 15.6in |
V45APF8000000S |
|
v450 PoE-Injector |
V4ZA0AP010000S |
Location in the network
These components are located in the automation pyramid at the control level. Furthermore, they are located in the security zone "CAP-Machine" (Zones and Conduits).
Location in the network
The components addressed here have one relevant interface:
-
Conduit: Industrial Ethernet
The visualization products are operated on the machine's internal network. If these components are operated outside this network, the consideration of cyber security is the responsibility of the operator. A cyber security risk analysis is recommended here.
-
Conduit: USB
The USB port (on board for the v430, can be realized via Y-cable for the v450) is only to be used for firmware updates and not for daily use. It is recommended to keep it deactivated.
Intended purpose
The intended use of these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.
-
These components mentioned here are professional equipment and may only be commissioned and decommissioned by specialists.
-
These components also require maintenance during their life cycle, which must be carried out by the operator.
-
Modifications to the firmware or hardware of the component are not permitted.
-
If these components are taken out of operation or disposed of, the instructions here in the documentation must be observed.
-
The USB stick used for a firmware update must be physically removed and not kept plugged in.
Intended environment
The intended environment for these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.
-
The visualization products are operated on the machine's internal network. If these components are operated outside this network, the consideration of cyber security is the responsibility of the operator. A cyber security risk analysis is recommended here.
-
The components are not operated directly on the open Internet, but must also be operated by the operator via protection systems such as firewall, IDS, IPS, ... be protected.
Security key indicators
Security key indicator (in accordance with IEC 62443-4-2):
-
These components are considered embedded devices (EDR).
-
These components have a security level of SL-C 0.
-
These components have an SL-vector from SL-C(v4x0)={ IAC=0; UC=0; SI=0; DC=0; RDF=0; TRE=0; RA=0 }