Areas of application

This function block provides an interface to the following functions of a connected AXIS_REF

  1. Manual release of the brake

  2. Resetting the tracking error

  3. Adaptation of controller settings

  4. Specification of an additive torque offset

  5. Activating the positive and negative torque limit

  6. Reading out device information

    • Current motor current - ActMotorCurrent

    • DC bus voltage-DC bus voltage

    • Thermal load Inverter-ThermalLoadDevice

    • Thermal load motor - ThermalLoadMotor

    • Current motor temperature - ActMotorTemperature

    • Target torque - SetTorque

If this function block is used on a Lenze Controller, the following outputs are only updated if the associated process data is contained in the EtherCAT mapping.

For more information on the respective objects, please refer to the description of the outputs.