L_TB2P_scSF_BasicMotionBase

Structure of the signal flow

Designator

Data type

Description

MP_xMulticoreActive

BOOL

 

TRUE

The technology module operates in multicore mode.

In this case, the associated AxisRef is processed on a different CPU core to the one on which the technology module is called.

FALSE

The technology module and the axis are implemented within the same core.

MP_AxisTaskIdx

INT

Task index of the task in which the axis and the associated calculations of the technology module are executed.

Note: When the application is downloaded, each task is assigned a unique but non-deterministic (random) index number.

MP_CallTaskIdx

INT

The task ID of the task from which the technology module is called.

Note: When the application is downloaded, each task is assigned a unique but non-deterministic (random) index number.

MP_xInternalControlActive

BOOL

TRUE

The axis’ internal control is activated via the visualisation system.