The following CODESYS clients do not support user management yet:
-
WebServer < V3.5.14.0
In order for these clients to be able to establish a connection to the controller, the user management must not be enabled.
The following CODESYS clients do not support encrypted communication yet:
-
Data server with compiler version =< V3.5.9.0
-
WebVisu < V3.5.14.0 or if file transfer is enabled
-
WebServer < V3.5.14.0
-
Remote TargetVisu
-
Data source ApplicationV3
-
OPC Server V3
-
PLCHandler < V3.5.14.0
In order for these clients to be able to establish a connection to the controller, the encrypted communication can be set as optional. Therefore clients can establish either an encrypted or an unencrypted connection.
|
Tip |
|---|---|
|
Do not use the same user or password for encrypted and unencrypted communication. For more information, see: Encrypting Communication, Changing Security Settings |