The FSoE parameters of a Safety Device are located on the Safe Configuration tab of the logical I/O of a Safety Device.
The variables that are used for the safety application to access the I/Os are defined on the I/O Mapping tab of the editor.
For a detailed description of the editor and the tab, see Logical I/O in the help of CODESYS Safety Extension.
The FSoE parameters comprise the general FSoE communication parameters for the configuration of safe communication, as well as in some cases also additional device-specific FSoE application parameters, which are described in the documentation of the device.
|
Caution |
|---|---|
|
For EtherCAT devices with several parallel FSoE connections, each one must have its own FSoE address specified. These different FSoE addresses of the same EtherCAT device must not be confused. |
-
FSoE address-
Address of the Safety Device (FSoE Slave)
(Position of the DIP switch),
-
The Value field is editable.
-
|
Caution |
|---|---|
|
The |
-
Connection ID-
Connection ID for the Safety Device
-
The Value field is editable.
-
|
Caution |
|---|---|
|
The For topology T2 when several safety controllers are used below the same EtherCAT master: The uniqueness of the FSoE connection IDs must be guaranteed in the entire EtherCAT network of the EtherCAT master. |
-
WatchdogTime-
The Value field is editable.
-
The parameters listed here are the FSoE communication parameters. These can still be followed by device-specific parameters (FSoE application parameters).
|
Tip |
|---|---|
|
The variant of FSoE application parameters, which are transferred to the device via FoE services (not via the safety controller), is not supported. |