The following commands lead to a switch to debug mode:
Commands in the "Online" menu
Commands in the Debug menu
|
Warning |
|---|---|
|
Each time when switching from the safe to the unsafe state of the safety controller the user must ensure that the organizational safety of the plant is guaranteed. |
|
Warning |
|---|---|
|
In debug mode, the safety controller is always in unsafe mode. It is the developers responsibility to ensure the safety of the plant by means of organizational measures. These measures must start before the release of the debug services and must be maintained until one of the following events occurs:
|
|
Caution |
|---|---|
|
For the release of debug services or the execution of commands in the case of multi-PLC projects, the developer must confirm the target name in a dialog so that the command is sent to the correct controller. |
The return of a safety controller from the unsafe to the safe state can take place by
-
Restart of the boot application
-
Switching the safety controller off and then on again
-
Reset origin of the boot application
-
Deletion of the boot application