Configuring the firewall

The firewall integrated in the controller can be used to restrict communication with the surrounding network.
The firewall is deactivated by default!
You can activate and configure the firewall using the "PLC Designer".
(Device tab
à
Settings
à
Communication
à
Firewall)
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5901:001
Security setting HAProxy: Certificate fingerprint
–
Read only
 
Display of the fingerprint (digital fingerprint) of the certificate for http/wss communication.
0x5901:002
Security setting HAProxy: HTTPS redirect
–
Read only
 
Display whether the visualization content of "EASY UI Designer" is redirected from HTTP to HTTPS or whether this setting is deactivated.
0
For EASY UI disabled
No redirection from HTTP to HTTPS. HTTP and HTTPS requests for visualization content ("EASY UI Designer") are answered directly.
1
For EASY UI enabled
HTTP requests for visualization content ("EASY UI Designer") are redirected. The website visitor is requested to use an HTTPS connection.
2
For EASY UI changing
Status feedback that the redirection from HTTP to HTTPS for visualization content has been changed.
3
HAProxy not active - No access
Status feedback that the redirection from HTTP to HTTPS for visualization content has not been changed because the HAProxy is not active.
255
Not valid
0x5910:001
Firewall: Activation
0
Deactivated
1
Activated
0x5910:002
Firewall: IP range 1 start
0 ... [0] ... 4294967295
Setting of IP range 1 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
0x5910:003
Firewall: IP range 1 end
0 ... [0] ... 4294967295
Setting of IP range 1 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
End of IP range 1 for permitted client IP addresses.
0x5910:004
Firewall: IP range 2 start
0 ... [0] ... 4294967295
Setting of IP range 2 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
0x5910:005
Firewall: IP range 2 end
0 ... [0] ... 4294967295
Setting of IP range 2 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
End of IP range 2 for permitted client IP addresses.
0x5910:006
Firewall: IP range 3 start
0 ... [0] ... 4294967295
Setting of IP range 3 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
0x5910:007
Firewall: IP range 3 end
0 ... [0] ... 4294967295
Setting of IP range 3 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
End of IP range 3 for permitted client IP addresses.
0x5910:008
Firewall: IP range 4 start
0 ... [0] ... 4294967295
Setting of IP range 4 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
0x5910:009
Firewall: IP range 4 end
0 ... [0] ... 4294967295
Setting of IP range 4 for permitted client IP addresses. The IP range defined here can be selected in the firewall settings for the various ports.
End of IP range 4 for permitted client IP addresses.
0x5911:001
Well-known ports: Secure Shell (SSH): Network
0 ... [0] ... 255
Network setting for the firewall to the "Secure Shell (SSH)" port.
–
SSH enables a secure, authenticated and encrypted connection between two computers via an insecure network.
 
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5911:002
Well-known ports: Secure Shell (SSH): Client IP range
Client IP range for the firewall to the "Secure Shell (SSH)" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5911:003
Well-known ports: Secure Shell (SSH): Activation
Action for the firewall to the "Secure Shell (SSH)" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5911:031
Well-known ports: Network Time Protocol (NTP): Network
0 ... [0] ... 255
Network setting for the firewall for the "Network Time Protocol (NTP)" port.
–
NTP functions as a time stamp during transmission and synchronizes the times of different systems down to the nanosecond.
 
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5911:032
Well-known ports: Network Time Protocol (NTP): Client IP range
Client IP range for the firewall to the "Network Time Protocol (NTP)" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5911:033
Well-known ports: Network Time Protocol (NTP): Activation
Action for the firewall for the "Network Time Protocol (NTP)" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5911:051
Well-known ports: Hypertext Transfer Protocol Secure (HTTPS): Network
0 ... [0] ... 255
Network setting for the firewall for the "Hypertext Transfer Protocol Secure (HTTPS)" port.
–
HTTPS is used to establish confidentiality and integrity in communication between the web server and web browser (client) on the World Wide Web. This is achieved through encryption and authentication, among others.
 
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5911:052
Well-known ports: Hypertext Transfer Protocol Secure (HTTPS): Client IP range
Client IP range for the firewall to the "Hypertext Transfer Protocol Secure (HTTPS)" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5911:053
Well-known ports: Hypertext Transfer Protocol Secure (HTTPS): Activation
Action for the firewall for the "Hypertext Transfer Protocol Secure (HTTPS)" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:001
Registered ports: PLC Designer TCP gateway search: Network
0 ... [0] ... 255
Network setting for the firewall for the "PLC Designer TCP gateway search" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:002
Registered ports: PLC Designer TCP gateway search: Client IP range
Client IP range for the firewall to the port "PLC Designer TCP gateway search".
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:003
Registered ports: PLC Designer TCP gateway search: Activation
Action for the firewall for the port "PLC Designer TCP gateway search".
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:011
Registered ports: PLC Designer UDP communication: Network
0 ... [0] ... 255
Network setting for the firewall for the "PLC Designer UDP communication" port.
–
The User Datagram Protocol (UDP) is a minimal, connectionless network protocol that belongs to the transport layer of the Internet protocol family.
 
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:012
Registered ports: PLC Designer UDP communication: Client IP range
Client IP range for the firewall to the "PLC Designer UDP communication" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:013
Registered ports: PLC Designer UDP communication: Activation
Action for the firewall for the "PLC Designer UDP communication" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:031
Registered ports: Lenze specific device-search (ESDCP): Network
0 ... [0] ... 255
Network setting for the firewall for the port "Lenze-specific device search (ESDCP)".
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:032
Registered ports: Lenze specific device-search (ESDCP): Client IP range
Client IP range for the firewall for the port "Lenze-specific device search (ESDCP)".
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:033
Registered ports: Lenze specific device-search (ESDCP): Activation
Action for the firewall for the port "Lenze-specific device search (ESDCP)".
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:041
Registered ports: OPC UA server: Network
0 ... [0] ... 255
Network setting for the firewall to the "OPC UA Server" port.
–
OPC UA (Open Platform Communications Unified Architecture) is a collection of standards for communication and data exchange in the field of industrial automation.
 
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:042
Registered ports: OPC UA server: Client IP range
Client IP range for the firewall to the "OPC UA Server" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:043
Registered ports: OPC UA server: Activation
Action for the firewall to the "OPC UA Server" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:051
Registered ports: EtherCAT master diagnostic tool: Network
0 ... [0] ... 255
Network setting for the firewall to the "EtherCAT master diagnostics tool" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:052
Registered ports: EtherCAT master diagnostic tool: Client IP range
Client IP range for the firewall to the "EtherCAT master diagnostics tool" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:053
Registered ports: EtherCAT master diagnostic tool: Activation
Action for the firewall to the "EtherCAT master diagnostics tool" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:061
Registered ports: UI designer RAW: Network
0 ... [0] ... 255
Network setting for the firewall for the "UI Designer RAW" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:062
Registered ports: UI designer RAW: Client IP range
Client IP range for the firewall to the "UI Designer RAW" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:063
Registered ports: UI designer RAW: Activation
Action for the firewall for the "UI Designer RAW" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:071
Registered ports: UI designer secure RAW: Network
0 ... [0] ... 255
Network setting for the firewall for the "UI Designer secure-RAW" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:072
Registered ports: UI designer secure RAW: Client IP range
Client IP range for the firewall to the "UI Designer secure-RAW" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:073
Registered ports: UI designer secure RAW: Activation
Action for the firewall for the "UI Designer secure-RAW" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:091
Registered ports: PLC Designer gateway: Network
0 ... [0] ... 255
Network setting for the firewall for the "PLC Designer Gateway" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:092
Registered ports: PLC Designer gateway: Client IP range
Client IP range for the firewall to the "PLC Designer Gateway" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:093
Registered ports: PLC Designer gateway: Activation
Action for the firewall for the "PLC Designer Gateway" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:101
Registered ports: Lenze specific engineering access (SFTP/SCP): Network
0 ... [0] ... 255
Network setting for the firewall for the port "Lenze-specific engineering access (SFTP/SCP)".
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:102
Registered ports: Lenze specific engineering access (SFTP/SCP): Client IP range
Client IP range for the firewall to the port "Lenze-specific engineering access (SFTP/SCP)".
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:103
Registered ports: Lenze specific engineering access (SFTP/SCP): Activation
Action for the firewall for the port "Lenze-specific engineering access (SFTP/SCP)".
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:131
Registered ports: SFTP/SCP: Network
0 ... [0] ... 255
Network setting for the firewall for the "SFTP/SCP" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:132
Registered ports: SFTP/SCP: Client IP range
Client IP range for the firewall to the "SFTP/SCP" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:133
Registered ports: SFTP/SCP: Activation
Action for the firewall for the "SFTP/SCP" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5912:151
Registered ports: OPC UA PubSub (UADP): Network
0 ... [0] ... 255
Network setting for the firewall for the "OPC UA PubSub (UADP)" port.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5912:152
Registered ports: OPC UA PubSub (UADP): Client IP Range
Client IP range for the firewall to the "OPC UA PubSub (UADP)" port.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5912:153
Registered ports: OPC UA PubSub (UADP): Activation
–
Read only
 
Action for the firewall for the "OPC UA PubSub (UADP)" port.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5913:001
Application ports: Application port 1: Network
0 ... [0] ... 255
Network setting for firewall to application port 1.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5913:002
Application ports: Application port 1: Client IP range
Client IP range for the firewall to application port 1.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5913:003
Application ports: Application port 1: Activation
Action for the firewall to application port 1.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5913:007
Application ports: Application port 1: Protocol type
Permitted protocols for the firewall to application port 1.
0
None
TCP and UDP protocols are blocked.
1
TCP
Only TCP protocols are allowed, UDP protocols are blocked.
2
UDP
Only UDP protocols are allowed, TCP protocols are blocked.
3
TCP & UDP
TCP and UDP protocols are permitted.
0x5913:008
Application ports: Application port 1: Port range start
0 ... [0] ... 65535
Start of the port range used for application port 1.
0x5913:009
Application ports: Application port 1: Port range end
0 ... [0] ... 65535
End of the port range used for application port 1.
0x5913:010
Application ports: Application port 1: Protocol name
["0"]
Freely selectable name as a guide for programmers for application port 1. This name is for information purposes only and has no function.
0x5913:011
Application ports: Application port 2: Network
0 ... [0] ... 255
Network setting for the firewall to application port 2.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5913:012
Application ports: Application port 2: Client IP range
Client IP range for the firewall to application port 2.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5913:013
Application ports: Application port 2: Activation
Action for the firewall to application port 2.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5913:017
Application ports: Application port 2: Protocol type
Permitted protocols for the firewall to application port 2.
0
None
TCP and UDP protocols are blocked.
1
TCP
Only TCP protocols are allowed, UDP protocols are blocked.
2
UDP
Only UDP protocols are allowed, TCP protocols are blocked.
3
TCP & UDP
TCP and UDP protocols are permitted.
0x5913:018
Application ports: Application port 2: Port range start
0 ... [0] ... 65535
Start of the port range used for application port 2.
0x5913:019
Application ports: Application port 2: Port range end
0 ... [0] ... 65535
End of the port range used for application port 2.
0x5913:020
Application ports: Application port 2: Protocol name
["0"]
Freely selectable name as a guide for programmers for application port 2. This name is for information purposes only and has no function.
0x5913:021
Application ports: Application port 3: Network
0 ... [0] ... 255
Network setting for the firewall to application port 3.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5913:022
Application ports: Application port 3: Client IP range
Client IP range for the firewall to application port 3.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5913:023
Application ports: Application port 3: Activation
Action for the firewall to application port 3.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5913:027
Application ports: Application port 3: Protocol type
Permitted protocols for the firewall to application port 3.
0
None
TCP and UDP protocols are blocked.
1
TCP
Only TCP protocols are allowed, UDP protocols are blocked.
2
UDP
Only UDP protocols are allowed, TCP protocols are blocked.
3
TCP & UDP
TCP and UDP protocols are permitted.
0x5913:028
Application ports: Application port 3: Port range start
0 ... [0] ... 65535
Start of the port range used for application port 3.
0x5913:029
Application ports: Application port 3: Port range end
0 ... [0] ... 65535
End of the port range used for application port 3.
0x5913:030
Application ports: Application port 3: Protocol name
["0"]
Freely selectable name as a guide for programmers for application port 3. This name is for information purposes only and has no function.
0x5913:031
Application ports: Application port 4: Network
0 ... [0] ... 255
Network setting for the firewall to application port 4.
Bit  0
Engineering port
Setting for diagnostic interface X16 for a connection to the "EASY Starter". The "EASY Starter" can be used as a diagnostic tool and for commissioning.
Bit  1
Fieldbus slave
Bit  2
Dual network
0x5913:032
Application ports: Application port 4: Client IP range
Client IP range for the firewall to application port 4.
0
Any
All client IP addresses are permitted.
1
IP range 1
Only clients in the IP range 1 (0x5910:002 ... 0x5910:003) are permitted.
2
IP range 2
Only clients in the IP range 2 (0x5910:004 ... 0x5910:005) are permitted.
3
IP range 3
Only clients in the IP range 3 (0x5910:006 ... 0x5910:007) are permitted.
4
IP range 4
Only clients in the IP range 4 (0x5910:008 ... 0x5910:009) are permitted.
0x5913:033
Application ports: Application port 4: Activation
Action for the firewall to application port 4.
0
Drop
Reject the connection, do NOT notify the sender.
1
Reject
Reject the connection, notify the sender.
2
Allow
Allow connection.
0x5913:037
Application ports: Application port 4: Protocol type
Permitted protocols for the firewall to application port 4.
0
None
TCP and UDP protocols are blocked.
1
TCP
Only TCP protocols are allowed, UDP protocols are blocked.
2
UDP
Only UDP protocols are allowed, TCP protocols are blocked.
3
TCP & UDP
TCP and UDP protocols are permitted.
0x5913:038
Application ports: Application port 4: Port range start
0 ... [0] ... 65535
Start of the port range used for application port 4.
0x5913:039
Application ports: Application port 4: Port range end
0 ... [0] ... 65535
End of the port range used for application port 4.
0x5913:040
Application ports: Application port 4: Protocol name
["0"]
Freely selectable name as a guide for programmers for application port 4. This name is for information purposes only and has no function.