Firmware update mode for field devices

The "Field device firmware update" parameter is used to define whether and under which conditions the firmware is automatically updated after the firmware versions have been compared.
 
This function applies to inverters that support firmware download, e.g. frequency inverter i550 cabinet.
 
The firmware and the settings of the inverter parameters are saved together with the "PLC Designer" project.
During start-up, the Lenze Controller checks whether the firmware version and the parameter settings of the inverter match the data stored in the project for this device.
When comparing the firmware versions, pay particular attention to the major version. The firmware consists of four groups of 2 digits each. The groups are separated by periods. The first group indicates the major version, e.g. 06.xx.xx.xx
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5820:001
Field devices: Field devices firmware update
0
Disabled
The firmware update is deactivated.
The controller does not perform a firmware download, but immediately starts the parameter set download to the inverter (EtherCAT slave). When the parameter set download has been successfully completed, the controller sets the EtherCAT bus to OPERATIONAL state.
This setting can be used if devices with an older firmware version are attached to the EtherCAT.
1
Enabled. Slave FW = config. FW
A firmware update is performed when the firmware of the inverter has the following version:
–
identical major version
 
–
different firmware
 
Example: Inverter: 06.01.xx.xx, PLC project / controller: 06.02.xx.xx
After the firmware download, the parameter set download to the inverter (EtherCAT slave) starts. When the parameter set download has been successfully completed, the controller sets the EtherCAT bus to OPERATIONAL state.
If the major version is not the same, no firmware update is performed. The EtherCAT bus remains in the PRE-OPERATIONAL state.
2
Enabled. Slave FW > config. FW
Four cases must be considered in this setting:
–
Case 1: The firmware of the inverter is identical to the firmware archived in the controller.
 
–
No firmware download is performed.
 
–
After the firmware download, the parameter set download to the inverter (EtherCAT slave) starts. When the parameter set download has been successfully completed, the controller sets the EtherCAT bus to OPERATIONAL state.
 
 
–
Case 2: The major version of the inverter firmware is greater than the major version of the firmware archived in the controller.
 
–
No firmware download is performed.
 
–
The controller starts the parameter set download to the inverter (EtherCAT slave). When the parameter set download has been successfully completed, the controller sets the EtherCAT bus to OPERATIONAL state.
 
 
–
Case 3: The major version of the inverter firmware is the same as the major version of the firmware archived in the controller.
 
–
A firmware download is performed.
 
–
After the firmware download, the parameter set download to the inverter (EtherCAT slave) starts. When the parameter set download has been successfully completed, the controller sets the EtherCAT bus to OPERATIONAL state.
 
 
–
Case 4: The major version of the inverter firmware is less than the major version of the firmware archived in the controller.
 
–
No firmware download is performed.
 
–
No parameter set download is performed.
 
–
The EtherCAT bus remains in the PRE-OPERATIONAL state.
 
 
 
Please note that even in case of a failed parameter set download, the EtherCAT bus does not leave the PRE-OPERATIONAL state.
If the cause preventing the state transition to OPERATIONAL has been eliminated (e.g. by replacing the inverter or updating the parameter set), the network must be restarted.
Learn how to restart the network in chapter Restart network .