PLC diagnostics

The following information may be retrieved for diagnostic purposes:
–
Information on the event currently active in the controller (event monitor)
 
–
Status of the SD card
 
–
Available application credit / required application credit
 
–
Dual use license
 
–
Temperature of the control card and CPU
 
–
Status of the application
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2010:001
Device event monitor: EreignisortEvent location
–
Read only
 
Display of the event location for the currently pending event.
0
No error
1
Functional safety
4
Basic settings
5
Communication
6
Kinematics
7
Motion
8
Technology application
9
Process control
0x2010:002
Device event monitor: Severity
–
Read only
 
Display of the severity level for the currently active event.
0
No response
1
Fault > CiA402
2
Warning
3
Fault
11
Information
13
Warning locked
15
Trouble > only logbook entry
16
Trouble
18
Fault > only logbook entry
19
Fault > Application quick stop > Quick stop
20
Fault > inverter quick stop > quick stop
21
Fault > inverter quick stop > inverter disabled
23
Fault > inverter disabled
0x2010:003
Device event monitor: Event status
–
Read only
 
Display of the event status for the currently pending event.
0
No event active
1
Reset possible
2
Reset not possible
0x2010:005
Device event monitor: Number of current event
–
Read only
 
Display of the event ID for the currently pending event.
0x2010:006
Device event monitor: Time stamp of current event
–
Read only
 
Display of the time stamp for the current upcoming event.
0x2010:007
Device event monitor: Event CRC
–
Read only
 
0x2012:001
Device information: SD card status
–
Read only
 
Display whether an SD card is inserted.
0
No SD card connected
1
SD card connected
0x2012:002
Device information: Application Credit available
–
Read only
 
Display of the application credit available on the SD card
0x2012:003
Device information: Dual use licence
–
Read only
 
Display whether a dual-use license is available.
0
Not available
1
Available
0x2012:004
Device information: SD card total memory
–
Read only
 
Display of the total memory capacity of the SD card in kilobytes.
0x2012:005
Device information: SD card free memory
–
Read only
 
Display of the currently free memory on the SD card in kilobytes.
0x2012:006
Device information: SD card used memory
–
Read only: x kB
 
Display of the currently occupied memory on the SD card in kilobytes.
0x2012:007
Device information: License information
–
Read only
 
Display of license information (format: "x.x.x") with the following meaning:
–
0.0.0: No license available
 
–
155.0.0: Visualization license available for c550
 
0x2013:001
Application information: Active application
–
Read only
 
Display of the active application.
0
CiA 402
1
TA CiA402 advanced
10
TA Speed Control
20
TA Table Positioning
40
TA Electronic Gearbox
41
TA Sync and Correction
50
TA Winder Dancer
51
TA Winder Tension
100
TA User
0x2013:002
Application information: Application Credit required
–
Read only
 
Display of the application credit required for the loaded application.
0x2539:002
Hardware-Diagnose: Control board temperature
–
Read only: x °C
 
Interior temperature of the device.
0x2539:003
Hardware-Diagnose: CPU temperature
–
Read only: x °C
 
Processor temperature of the device.
0x2D85:001
Fan diagnostics: Status
–
Read only: x %
 
Fan status in %
–
0% = Fan off
 
–
30%...100% = Speed in %
 
0x2D85:002
Fan diagnostics: Speed
–
Read only: x rpm
 
Speed in rpm.
0x5810:001
Application diagnostics: Application state
–
Read only
 
0
Unknown/application missing
1
Running
2
Stopped
3
Stopped at breakpoint
0x5810:002
Application diagnostics: Used memory size
–
Read only: x kB
 
Display of the memory used by the application in kilobytes.