Set IP address on the PC
Recommended IP address of the engineering PC: 192.168.5.100
Standard IP address of the engineering port X16 on the controller: 192.168.5.99
How to set the static IP address of the Engineering PC:
Preconditions
✓
Direct connection between the engineering PC and the controller
1.
Open the Network connections diagnostics window.
Control Panel\Network and Internet\Network Connections
2.
Select the network interface which is connected to the controller.
3.
Right-click on Properties.
4.
Select Internet Protocol (TCP/IP).
5.
Click on the Properties button.
6.
Select the Alternate Configuration tab.
7.
Select the User-defined option.
a.
Enter the IP address of the engineering PC that matches the IP range of the controller.
b.
Enter the subnet mask of the engineering PC.
8.
Click OK to close the dialog box.