Parameter data transfer

The EtherCAT device possesses two categories of parameters:
–
Standard communication parameters (index range 0x1000 ... 0x1FFF and 0xF050, Detected Module List).
These parameters are only visible/accessible for the EtherCAT masters connected via this interface.
The controller itself is unable to access the standard communication parameters.
 
–
For diagnostic parameters, see EtherCAT device diagnostics
 
Standard communication parameters
Address
Name / setting range / [default setting]
Information
0x1000
Device type
RO
0x1001
Error register
RO
0x1008
Manufacturer's device name
RO
0x1009
Manufacturer's hardware version
RO
0x100A
Manufacturer's software version
RO
0x1018
Identity object
RO
0x1630
0x164F
RxPDO mapping
RW
0x1A30
0x1A4F
TxPDO mapping
RW
0x1C00
Sync manager type
RO
0x1C12
SM2 PDO assignment
RW
0x1C13
SM3 PDO assignment
RW
Tab. 1: Standard communication parameters (via EtherCAT interface)
 
Address
Name / setting range / [default setting]
Information
0xF050
Detected module list
RO/ARRAY OF UDINT
Array with objects of type "UDINT" which contains the currently configured/detected modules. Can be used for a device scan for reading the current configuration.
SubIndex 0 (USINT) contains the currently configured/detected number of modules.
Tab. 2: Detected module list (via EtherCAT interface)