Function of keypad keys in operating mode

In the operating mode, the keypad can be used for local control and for manual setpoint selection.
 
Function of keypad keys in operating mode
Key
Actuation
Condition
Action
Briefly
Local keypad control active.
Display "LOC"
Run motor.
Remote control active
Display "REM"
Display "KSTOP"
Deactivate keypad triggered stop.
The motor remains at standstill.
Display changes from "KSTOP" to "STOP".
Briefly
No Jog operation
Stop motor.
Display "KSTOP"
Briefly
Operating mode
Change to parameterisation mode.
Longer than 3 s
None (anytime possible)
Save parameter settings in the user memory of the memory module.
Briefly
During operation
Scroll through information in the above status line.
Briefly
Manual setpoint selection via keypad active.
Display "MAN"
Change frequency setpoint.
Briefly
Operating mode
Activate full keypad control
Display "ON?"
à
Confirm with
Control and setpoint selection can now only be carried out via keypad.
Renewed clicking: Exit full keypad control.
Display "OFF?"
à
Confirm with
Briefly
Local keypad control active.
Display "LOC"
Reversal of rotation direction.
Display "REV?"
à
Confirm with
 
Example: Change setpoint