Suppress certain alarm / emergency messages to the master
To simplify the error handling between a master and the inverter, a function for suppressing diagnostic or alarm messages is implemented. If desired, the user can suppress the display of alarm responses in the master.
Usually, all errors occurring in the device are reported to a connected PLC if an alarm / emergency mechanism with the connected communication system is supported. In order to suppress certain alarm / emergency messages, this filter mechanism selects the error messages that shall not be reported to the PLC.
In object 0x285C, the corresponding error numbers are given in n subindex. Up to n = 10 error numbers can be selected.
If the "0xFFFFFFFF" error code is found in one of the subindices, all messages are blocked.
Parameter