Status LEDs

The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick information about certain operating states.
 
"RDY" LED (blue)
"ERR" LED (red)
Status/meaning
off
off
No supply voltage
on
on
Initialisation (inverter is started)
blinking (2 Hz)
off
Inverter disabled
blinking fast (4 Hz)
Inverter disabled, warning present.
on
Inverter disabled, error active.
on briefly every 1.5 s
Inverter disabled, no DC-bus voltage.
on briefly every 1 s
USB module is connected, 5-V supply voltage for the USB module is available.
on
off
Inverter enabled. The motor rotates according to the specified setpoint or quick stop active.
blinking fast (4 Hz)
Inverter enabled, warning present. The motor rotates according to the specified setpoint or quick stop active.
blinking (1 Hz)
Inverter enabled, quick stop as response to fault active.
Both LEDs are blinking in a rapidly alternating mode
Firmware update is active
Both LEDs are blinking in a very rapidly synchronous mode
"Visual tracking" function is active