Configure reset behaviour
For some customers it is a common method to always have the same starting conditions of the parameters.
This function allows a user to exclude certain parameter groups from being reset to the default settings using the "Load default settings" device command.
Details
By default, all parameters are reset when the default settings are loaded.
The user can reconfigure this function.
Thus, certain parameter groups can be excluded.
The following cannot be selected for the reset:
–
address of the communication bus,
–
data format,
–
baud rate,
–
subnet mask,
and for WLAN:
–
channel,
–
safety,
–
network password,
–
SSID name.
Your setting values remain stored.
Please make sure that bit 0 must be set to 1 in the parameter 0x2024:001 before executing the default settings in order that the network parameters are excluded from the reset.
Note that the purpose of this function is to enable the master to restore the connection to an inverter after loading the default settings. Because all data mapping and functional settings are reset, the user must let the master reconfigure the settings of the inverter before it operates the inverter.
Parameter
0x2022:001 (P700.01)