Configuring the feedback system

The Inverter i550 exclusively supports HTL encoders.
 
An HTL encoder can be used at the Inverter i550 for the following tasks:
–
As motor encoder for a motor speed feedback for speed control that is as precise as possible (SC-ASM) Servo control for asynchronous motor (SC-ASM) .
 
–
As a setpoint encoder for defining a frequency setpoint Standard setpoint source .
 
–
As setpoint encoder for defining the reference value for the process controller Configuring the process controller .
 
–
As a setpoint encoder for defining a torque setpoint Configure setpoint sources .
 
–
As actual value encoder for the process controller Configuring the process controller .
 
–
As actual value encoder for the "position counter" function Process output data .
 
The HTL encoder connected to the inverter is not automatically set as the feedback system for motor control if a motor is selected from the motor catalogue!
 
 
The information in the following chapters generally applies for the HTL encoder, regardless of its purpose.