Required commissioning steps
1.
2.
Activate motor control type: 0x2C00 (P300.00) = "Servo control (SC ASM) [2]".
3.
Carry out optimisation of the control circuits.
–
An optimum operation of this motor control type requires an optimisation of the control loops!
–
4.
Alternatively, the inverter can be configured in this motor control type in such a way that it controls a motor torque within a defined frequency range. For details, see chapter "Configuring the torque control".
5.
Optionally for a speed control with torque limitation in operating mode 0x6060 (P301.00) = "MS: Velocity mode [-2]":
–
Select the source in 0x2949:001 (P337.01) for the positive torque limit source and set it accordingly.
–
Select the source in 0x2949:002 (P337.02) for the negative torque limit source and set it accordingly.
Options for optimizing the control loops