Synchronous motor: Pole position identification (PPI)

For the control of a permanent-magnet synchronous motor, the pole position – the angle between motor phase U and the field axis of the rotor – must be known. The determination of this angle can be done by a so called "Pole Position Identification (PLI)".
 
Preconditions
The function is only available for sensorless control.
 
The "Pole position identification (PPI) without movement" function is available for the identification of the pole position for the inverter i5xx.