Safety-related characteristics Basic Safety - STO
Safety-related characteristics according to EN 61508, Part 1-7 and EN 62061
|
Specification
|
Value
|
Comment
|
|
Safety Integrity Level
|
SIL 3
|
|
|
PFH [1/h]
|
1.71 E−09
|
1.71 % of SIL 3
|
|
PFDavg (T)
|
1.49 E−04
|
14.9 % of SIL 3 after T = 20 years
|
|
Proof test interval
|
20 years
|
Mission time
|
Safety-related characteristics according to EN ISO 13849-1
|
Specification
|
Value
|
Comment
|
|
Performance Level
|
e
|
|
|
Category
|
4
|
|
|
MTTFd
|
High
|
3200 years
|
|
Mean diagnostic coverage DCav
|
High
|
99 %
|
Basics of the safety-related characteristics
|
Basics
|
Value
|
Comment
|
|
Source of failure rates
|
SN 29500
|
When no values from the component manufacturers were available.
|
|
Average max. ambient temperature
|
40 °C
|
|
Further data and information can be found in the corresponding project planning document in the "Electrical installation" chapter.