Safety-related characteristics Basic Safety - STO

Safety-related characteristics according to EN 61508, Part 1-7 and EN 62061
Specification
Value
Comment
Safety Integrity Level
SIL 3
PFH [1/h]
1.71 E−09
1.71 % of SIL 3
PFDavg (T)
1.49 E−04
14.9 % of SIL 3 after T = 20 years
Proof test interval
20 years
Mission time
 
Safety-related characteristics according to EN ISO 13849-1
Specification
Value
Comment
Performance Level
e
Category
4
MTTFd
High
3200 years
Mean diagnostic coverage DCav
High
99 %
 
Basics of the safety-related characteristics
Basics
Value
Comment
Source of failure rates
SN 29500
When no values from the component manufacturers were available.
Average max. ambient temperature
40 °C
 