Source of monitoring signal

A monitoring signal can be selected for status word 6 and status word 7 respectively.
–
Selection for status word 6: 0x5040:006
 
–
Selection for status word 7: 0x5040:007
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5040:006
Display value 1
Signal selection for the monitoring of signal 1 to status word 6.
1
Actual motor temperature
2
Actual motor current
3
DC-bus voltage
4
Device utilisation
5
Motor utilisation
6
Analog input 1
13
Total velocity offset
16
Actual scaled torque
17
Set position
18
Set velocity
19
Set acceleration
20
Set torque
21
Actual motor speed
22
Following error
23
Digital inputs
0x5040:007
Display value 2
Signal selection for the monitoring of signal 2 to status word 7.
0
None
1
Actual motor temperature
2
Actual motor current
3
DC-bus voltage
4
Device utilisation
5
Motor utilisation
6
Analog input 1
13
Total velocity offset
16
Actual scaled torque
17
Set position
18
Set velocity
19
Set acceleration
20
Set torque
21
Actual motor speed
22
Following error
23
Digital inputs
0x5040:116
Display value 1
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 1"
Selection: 0x5040:006
0x5040:117
Display value 2
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 2"
Selection: 0x5040:007