Touch probe status word

Status words of the touch probe functionality.
–
CiA status word(Touch probe 1/2): 0x60B9
 
–
Extended status word (Touch probe 3/4, manufacturer-specific): 0x2D02:002
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x60B9
Touch probe status
–
Read only
 
Status of the touch probe functionality.
Bit  0
TP1 active
0: touch probe channel 1 deactivated.
1: touch probe channel 1 activated.
Bit  1
TP1 pos. edge detected
0: position not detected.
1: position detected.
Bit  2
TP1 neg. edge detected
Bit  6
TP1 level at enable start
Level for detection via touch probe channel 1
0: LOW level
1: HIGH level
Bit  8
TP2 active
0: touch probe channel 2 deactivated.
1: touch probe channel 2 activated.
Bit  9
TP2 pos. edge detected
0: position not detected.
1: position detected.
Bit  10
TP2 neg. edge detected
Bit  14
TP2 level at enable start
Level for detection via touch probe channel 2
0: LOW level
1: HIGH level
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2D02:002
Touch probe diagnostics: Touch-Probe 3/4 status
–
Read only
 
Bit  0
Touch-Probe 3 ist aktiviert
Bit  1
Touch-Probe 3 - Position erfasst fallende Flanke
Bit  2
Touch-Probe 3 - Position erfasst steigende Flanke
Bit  6
Touch-Probe 3 - Pegel bei Zeitstempel
Bit  8
Touch-Probe 4 ist aktiviert
Bit  9
Touch-Probe 4 - Position erfasst fallende Flanke
Bit  10
Touch-Probe 4 - Position erfasst steigende Flanke
Bit  14
Touch-Probe 4 - Pegel bei Zeitstempel