General information and basics

Functional safety describes the necessary measures that need to be taken by means of electrical or electronic equipment to prevent or eliminate dangers due to functional errors.
Protective devices prevent any human access to dangerous areas during normal operation. However, persons may have to be in the danger areas in certain operating modes. The machine operator is protected by internal drive and control measures in these operating modes.
 
Integrated functional safety
Integrated functional safety provides the conditions in the controls and drives to implement protective functions. Planning and installation expenditure is reduced. Using integrated functional safety increases machine functionality and availability. Integrated functional safety can be used for the protection of persons working on machines in accordance with the Machinery Directive.
 
Safety component
The safety component in the inverter provides the safe interfaces (e.g. safe inputs or safe network interfaces). If the STO safety function is requested, the safety component immediately brings about the torque-free state according to EN 61800-5-2.
 
In the "Advanced Safety" or "Extended Safety" version, the safety component also monitors safe compliance with the limit values. If monitored limit values are exceeded, the safety component reacts with safety functions according to EN 61800-5-2.
 
Identification of the components
The functional safety components and the associated connections are usually marked in yellow. Since the functional safety standards do not prescribe color coding, the components and terminals can also be designed in other colors.
 
Standards
Safety regulations are confirmed by laws and other governmental guidelines and measures and the prevailing opinion among experts, e.g. by technical regulations.
 
The regulations and rules to be applied must be observed in accordance with the application.
 
Risk assessment
This documentation can only accentuate the need for a risk assessment. The user of the integrated functional safety must read up on standards and the legal situation.
 
Before a machine can be put into circulation, the manufacturer of the machine has to conduct a risk assessment according to the 2006/42/EC: Machinery Directive [UKCA: S.I. 2008/1597 - The Supply of Machinery (Safety) Regulations 2008] to determine the hazards associated with the use of the machine.
The Machinery Directive refers to three basic principles for the highest possible level of safety:
–
Hazard elimination / minimisation by the construction itself.
 
–
Taking the protective measures required against hazards that cannot be removed.
 
–
Existing residual hazards must be documented and the user must be informed of them.
 
 
Detailed information on the risk assessment is provided in the DIN EN ISO 12100:2013-08: Safety of machinery − General principles for design − Risk assessment and risk reduction. The result of the risk assessment determines the category for safety-related control systems according to EN ISO 13849-1. Safety-oriented parts of the machine control must be compliant.
 
Mission time
The mission time of the used components must be complied with.
In case of a defect or when the mission time of a component has expired, the complete component must be replaced. Continued operation is not permitted!
The mission time for the safety functions cannot be reset by a special proof test.
 
The specified mission time starts at the date of manufacture.
Mission timeSafety-related data