Cable check
This function serves to detect wiring errors or cable damage which can cause uncontrolled movements of the machine during the commissioning phase or during operation. The function therefore helps to prevent machine damage and serves to correct these errors as quickly as possible.
The Cable Check function should be executed manually by the user while the machine is commissioned, in order to identify typical errors that may occur during the machine installation.
Typical errors
–
The motor encoders are connected to the wrong device before initial switch-on, whereas the motor is connected to the right device. If the motor encoders that are incorrectly connected are of the same type, the motor encoder monitoring does not detect any error.
–
The motor encoders are connected to the right device, however, the motor is connected to the wrong device.
–
The connection of the motor phases to the device is reversed.
–
Individual wires of the rotary transducer are connected incorrectly.
How to manually execute the Cable Check function:
Preconditions
✓
The motor can remain coupled to the kinematics.
–
In the case of drives without a motor holding brake, the rotor must be able to move by 20 ° (electrically). This makes it necessary to set the operating mode of the motor holding brake to "No brake connected".0x2820:001
0x2820:001 = 2
0x2820:001 = 2–
In the case of drives with a motor holding brake, the test is performed against the closed motor holding brake. In the following parameter, the operating mode must be set to 0 or 1. 0x2820:001
0x2820:001
0x2820:001✓
The device must not be in the Fault state.
✓
24 V supply voltage must be available.
✓
The display on the front of the blue LED shows ON or is blinking.
✓
The device must be supplied with mains voltage. Parameter status 0x6041, Bit 40x6041, Bit 4 = TRUE
✓
The device must not be in the STO state. The safety functions must be parameterized. Parameter status: 0x6041, Bit 15 0x6041, Bit 15 = FALSE
✓
The motor data must be set correctly.
✓
No error message must be active. Parameter status: 0x6041, Bit 3 0x6041, Bit 3 = FALSE. If an error message is active, first remove these errors and reset the error message.
✓
The motor control must be set to: The function only supports these two motor controls.
–
Servo control - synchronous motor (SM) or
–
Servo control - asynchronous motor (ASM)
✓
The behavior after switch-on must be set. 0x2C64 = 0.
1.
Open the
»
EASY Starter«
engineering tool.2.
Establish an online connection to the device.
3.
Call the Motor commissioning tab in the workspace of the
»
EASY Starter«
.4.
Call the Feedback tab there.
5.
In the jalousie Cable check: Motor and motor encoder, execute the Cable Check function.
The Cable Check function is now activated.
6.
Execution of the function is indicated as completed in the
»
EASY Starter«
after approx. one second. Additionally, the »
EASY Starter«
indicates whether an error has occurred during the check:The Cable Check function can always be started via the Execute Cable Check button if the preconditions for this are met.
No error detected by the Cable Check function
The device changes to the "Operation enabled" state.
–
Deactivate the device. e.g. via the control word. You can do this using keys F8 / F9 in the
»
EASY Starter«
.–
Deactivate the Cable Check function via the parameter and set a selection other than 15. 0x2825 0x2825
Error detected by the Cable Check function
If the Cable Check function detects an error, the i700 servo inverter automatically changes to the Fault status.
How to remove errors:
1.
Consult the logbook to identify the error causes.
2.
Switch off the power supply and 24 V supply of the device.
3.
Check the wiring and correct it, if necessary.
4.
Execute the test again.
The "Identification" status word is also used by other functions. The display is therefore only valid as long as no other function using this status word is active. 0x28320x2832
During operation, the Cable Check function can be automatically executed by the device itself, in order to detect damage on the motor or motor encoder already when the machines are switched on.
Damage during operation
Typical damage that may occur during operation
–
Wire breakage on the motor encoder and/or motor cable
–
Whole motor encoder cable and/or motor cable torn off
–
Screwed connections that are loosening
–
Loose contacts
Starting condition for the Cable Check
The following starting conditions can be set for the automatic Cable Check function:
–
Check only at initial switch-on or after motor encoder error 0x2641:001 0x2641:001 = 1
–
Check after every switch-on 0x2641:0010x2641:001 = 2
Observe the line diagrams for configuring the controller.
How to carry out the Cable check automatically
Preconditions
✓
The motor can remain coupled to the kinematics.
–
In the case of drives without a motor holding brake, the rotor must be able to move by 20 ° (electrically). This makes it necessary to set the operating mode of the motor holding brake to "No brake connected".0x2820:001
0x2820:001 = 2
0x2820:001 = 2–
In the case of drives with a motor holding brake, the test is performed against the closed motor holding brake. In the following parameter, the operating mode must be set to 0 or 1. 0x2820:001
0x2820:001
0x2820:001✓
The device must not be in the Fault state.
✓
24 V supply voltage must be available.
✓
The display on the front of the blue LED shows ON or is blinking.
✓
The device must be supplied with mains voltage. Parameter status 0x6041, Bit 40x6041, Bit 4 = TRUE
✓
The device must not be in the STO state. The safety functions must be parameterized. Parameter status: 0x6041, Bit 15 0x6041, Bit 15 = FALSE
✓
The motor data must be set correctly.
✓
No error message must be active. Parameter status: 0x6041, Bit 3 0x6041, Bit 3 = FALSE. If an error message is active, first remove these errors and reset the error message.
✓
The motor control must be set to: The function only supports these two motor controls.
–
Servo control - synchronous motor (SM) or
–
Servo control - asynchronous motor (ASM)
✓
The behavior after switch-on must be set. 0x2C64 = 0.
1.
Open the
»
EASY Starter«
engineering tool.2.
Establish an online connection to the device.
3.
Call the Motor commissioning tab in the workspace of the
»
EASY Starter«
.4.
Call the Feedback tab there.
5.
In the jalousie Cable check: Motor and motor encoder, execute the Cable Check function.
The Cable Check function is now activated.
6.
In a last step, changed settings must be saved with mains failure protection.
When the pole position identification is set after every switch-on and Cable Check, the pole position identification is carried out first, followed by the Cable Check.
Depending on the parameter setting in 0x2C64:1, the Cable Check starts automatically if the controller activates operation of the device via the CiA402 control word. The check takes approx. one second. During this time, 0x2C64, bit 1 is = TRUE A possibly available motor holding brake remains closed. In this case, the rotor is moved against the closed motor holding brake. If no motor holding brake is available, the rotor of the motor is moved electrically by approx. 20 °. The device remains in the switched-on state until the cable check has been completed.
The Cable Check function can always be started via the Execute Cable Check button if the preconditions for this are met.
Possible error sources
–
Failure of a motor phase
–
Incorrect direction of rotation detected.
Parameter