Data content and formats for the components
The naming of the hardware component data is based on OPC UA DI. This standard will also be the basis for asset management.
According to OPC UA DI, there are 11 properties of the device. Only the data relevant to the components is provided for the "Component Directory".
The naming of the software component data is based on the CycloneDX standard (OWASP CycloneDX is a full-stack Bill of Materials (BOM) standard that provides advanced supply chain capabilities for cyber risk reduction).
Data groups
Hardware components:
-
Controller
-
EtherCat devices: (inverter, IO, safety)
-
Name of the GlobalVariableList (GVL) in the PLC: "GVL_ComponentHardware"
-
Format: all strings (length should be the same as the parameter: 80 characters)
-
Supported parameters:
-
DeviceClass: Product category e.g. inverter
-
HW Revision: Hardware version of the device e.g. 1.8.0.34
-
Manufacturer: Manufacturer of the device
-
ProdCode: Product code
-
SerialNumber: individual unique serial number
-
SW revision: Software version of the device e.g. 1.10.0.1
-
Software components:
-
PLC program: PLC program written and versioned by the customer for a specific machine
-
Libraries for the FAST Runtime (CODESYS): Libraries from CODESYS, created by Lenze and by the customer.
-
Storage as CycloneDX file: "ComponentDirectoryApplicationSW.json"
-
Supported parameters:
-
"type": "library"
-
"publisher": "Lenze"
-
"name": "L_TB2P_TechModulesBasic"
-
"version": "3.19.0.53"
-