The correction values must consist of at least two interpolation points.
-
Equal indices <n> in alrAxisPosition[n] and alrAxisCorrection[n] correspond to a value pair / interpolation point, i.e. the correction value alrAxisCorrection[n] was measured at the point alrAxisPosition[n].
-
The vector of the position grid points alrAxisPosition must be specified in strictly monotonically increasing order.
- The respective final value is output outside the sampling points.
- The correction values are interpolated linearly between the interpolation points.
- If the axis is a modulo axis, the correction table must cover the entire cycle length of the modulo axis. The correction values at the beginning and end must also be continuous, i.e. the first and last correction values must be identical.