L_TS2P_scAP_CrossCutterState
Structure of the access points
|
Designator Data type |
Description |
|
|---|---|---|
|
AP_xEndOfProfileWindowSize BOOL |
||
|
Enabling the access point AP_lrEndOfProfileWindowSize TRUE The action point overwrites the value for the window function |
||
| AP_lrEndOfProfileWindowSize LREAL |
||
|
End-of-Profile Detection Using Window Function The application parameter (AP) defines the window function used for detecting xEndOfProfile. A larger window is required when the reference value is subject to noise, which causes fluctuations in the setpoint of the Y-position. To ensure reliable detection of the end of the profile, it is necessary to increase the window size. This helps to compensate for the noise and allows the system to correctly identify when the profile has been completed. |
||
| AP_xOverspeedUpperLimit BOOL |
||
|
Enabling the intervention point AP_lrOverspeedUpperLimit TRUE The intervention point overwrites the limits of the lrOverspeed function |
||
| AP_lrOverspeedUpperLimit LREAL |
||
|
Limiting the Input Value lrOverspeed The application parameter AP_lrOverspeedUpperLimit defines the maximum limit for the input value lrOverspeed. This means the input can reach up to the value of AP_lrOverspeedUpperLimit, but cannot exceed it.
|
||
|
AP_xDisableInternalControl BOOL |
TRUE |
Disable the InternalControl functionality of the technology module. If TRUE, the technology module cannot be controlled by the visualization template. |