L_TS2P_scAP_CrossCutterState

Structure of the access points

Designator

Data type

Description

 

AP_xEndOfProfileWindowSize

BOOL

Enabling the access point AP_lrEndOfProfileWindowSize

TRUE The action point overwrites the value for the window function

 

AP_lrEndOfProfileWindowSize

LREAL

End-of-Profile Detection Using Window Function

The application parameter (AP) defines the window function used for detecting xEndOfProfile. A larger window is required when the reference value is subject to noise, which causes fluctuations in the setpoint of the Y-position.

To ensure reliable detection of the end of the profile, it is necessary to increase the window size. This helps to compensate for the noise and allows the system to correctly identify when the profile has been completed.

 

AP_xOverspeedUpperLimit

BOOL

Enabling the intervention point AP_lrOverspeedUpperLimit

TRUE The intervention point overwrites the limits of the lrOverspeed function

 

AP_lrOverspeedUpperLimit

LREAL

Limiting the Input Value lrOverspeed

The application parameter AP_lrOverspeedUpperLimit defines the maximum limit for the input value lrOverspeed. This means the input can reach up to the value of AP_lrOverspeedUpperLimit, but cannot exceed it.

  • Initial value: 2

AP_xDisableInternalControl

BOOL

TRUE

Disable the InternalControl functionality of the technology module. If TRUE, the technology module cannot be controlled by the visualization template.