State machine of the technology module
State machine of the technology module
|
1 |
A transition to the ERROR or STOP state is possible. |
|
a |
In the "STANDBY" state, xEnableOperation has to be set to TRUE. |
|
b |
In the "ERROR" state, xResetError has to be set to TRUE in order to acknowledge and reset the errors. |
|
c |
The "EXTERNAL" state is set if a function generates setpoints for the connected axis outside the technology module, e.g. MC_CamIn , MC_MoveAbsolute . |
|
d |
eAxisState = "STANDSTILL" |
|
No. |
L_TB2P_States |
Description |
|---|---|---|
|
-1 |
DISABLED |
Technology module deactivated |
|
0 |
STANDBY |
Technology module is on standby |
|
1 |
STOP |
Stop/Halt active |
|
2 |
HOMING |
Homing active |
|
3 |
JOGGING |
Manual jog active |
|
4 |
MOVEVEL |
Continuous travel with a defined velocity active |
|
5 |
MOVEABS |
Absolute positioning active |
|
6 |
MOVEREL |
Relative positioning active |
|
7 |
EXTERNAL |
An external function generates setpoints for the connected axis |
|
8 |
ERROR |
Error state |
|
30 |
ACC_DEC_SYNC |
Synchronization function active |
|
32 |
POSITIONING_TO_START_POS |
Movement to start position active |
|
35 |
POSITIONING_TO_PARK_POS |
Movement to parking position active |
|
170 |
CUTTING |
Cutting function active |
|
1000 |
SYSTEMFAULT |
System fault |