Product description

Product identification

This documentation applies to the "Motor Driven Roller" product familyconsists of the following components and their identification:

Name of product and product ID

Name of product

Product ID

Motor Driven Roller

O45ASxxxxxxxxxxxxx

Location in the network

These components are located in the automation pyramid at the control level. Furthermore, they are located in the security zone "CAP-Field" (Zones and conduits).

Location in the Network

The components addressed here have one relevant interfaces:

  • Conduit: Field Level
    The Motor Driven Rollers are located in the process level and have only one interface for the external adapter which is located at the field level-This adapter realizes the conduit field level. The Motor Driven Roller interface is not designed as a data fieldbus, but as a dedicated I/O interface. The limited data-related functions are described below.

Intended purpose

The intended use of these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.

  • These components are professional equipment and may only be commissioned and decommissioned by specialists.

  • These components also require maintenance during their life cycle, which must be carried out by the operator.

  • Modifications to the firmware or hardware of the component are not permitted.

  • If these components are taken out of operation or disposed of, the instructions here in the documentation must be observed.

Intended environment

The intended environment for these components is described in the application as directed and can be found in the operating instructions for the respective component. In the following, some specifics regarding cyber security are discussed.

  • As these components are decentralized, a closed control cabinet is out of the question. Therefore, physical access protection is required.

  • The components are not operated directly on the open Internet, but must also be operated by the operator via protection systems such as firewall, IDS, IPS, … .

  • Deactivate all unused interfaces and/or protocols, both for the components mentioned here and for all components that are connected to the network.

  • The more security-critical an application is, the more systems should be separated. Only combine tasks on one component if they are in the same risk classification.

  • Wherever possible, use a Defense-in-Depth Concept in the environment of this component.

  • Use appropriate authentication mechanisms. This applies, for example, to passwords that have the necessary complexity and an appropriate life cycle. The current state of the art must be taken into account here.

  • Handle secrets, such as passwords, appropriately. The focus here is on the handling of secrets on the components noted here, but also on the data stored in the environment of these components.

  • Validate all input options for validity. Pay attention to all human user interfaces as well as the machine software interfaces.

  • Evaluate the environment, the technical task to be performed and the existing component security in a security-critical consideration and assess whether additional protective measures are necessary for your application.

Security key indicators

Security key indicator (in accordance with IEC 62443-4-2):

  • These components are considered embedded devices (EDR).

  • These components have a security level of SL-C 0, because no certification was carried out.

  • These components have the technical functionality to enable an SL-vector from SL-C(MotorDrivenRoller)={ IAC=n.a.; UC=1; SI=1; DC=n.a.; RDF=n.a.; TRE=n.a.; RA=1 }.