Connection via OPC Diagnostic Server

To establish a connection, a diagnostic adapter or module must be connected between the PC and the online device.

The allocation is shown in the following table:

Device

Diagnostic adapter / module

  • Inverter Drives 8400 BaseLine

  • Inverter Drives 8400 HighLine

  • Inverter Drives 8400 TopLine

  • Servo Drive 9400 HighLine

USB diagnostic adapter E94AZCUS

  • Inverter i510

  • Inverter i550

USB module i5MADU0000000S

  • To establish a connection to the online device:

  1. Click on the Windows™ Start button.

  2. Enter the command cmdin the command line.

    • A new instance of the Windows command interpreter is started.

  3. Enter the command for establishing the connection.

    Note: Enter " DDCMP:/" in the command.

    Example:

    start /d "Programme path path>" MaintenanceTool.exe - Connection 85736b63-990e-445e-925b-95d98d357f99\DDCMP:/

Programme example

You can use the following programme example as a basis for creating a batch file, taking into account the syntax and the programme path:

@echo off

goto :EndOfComment

==========================================================

This batch file starts the EASY Starter 1.14

and inserts 1 online device over the connection 'OPC Diagnostics Server'.

Prerequisites:

The device must be connected to the PC via one of the following adapters:

Diagnosis adapter E94AZUS

USB Module i5MADU0000000S

How to specify the address of the device:

If a single adapter is plugged to the PC, just specify 'DDCMP:/'.

If several adapters are plugged to the PC, specify 'DDCMP:/HW'

followed by the hardware serial number of the adapter to be used,

followed by another '/', e.g. 'DDCMP:/HW123/'.

==========================================================

EndOfComment

start /d "<programme path>" MaintenanceTool.exe -Connection 85736b63-990e-445e-925b-95d98d357f99\DDCMP:/