Connection via OPC Diagnostic Server
To establish a connection, a diagnostic adapter or module must be connected between the PC and the online device.
The allocation is shown in the following table:
|
Device |
Diagnostic adapter / module |
|---|---|
|
USB diagnostic adapter E94AZCUS |
|
USB module i5MADU0000000S |
-
To establish a connection to the online device:
-
Click on the Windows™ Start button.
-
Enter the command cmdin the command line.
-
A new instance of the Windows command interpreter is started.
-
-
Enter the command for establishing the connection.
Note: Enter " DDCMP:/" in the command.
Example:
start /d "Programme path path>" MaintenanceTool.exe - Connection 85736b63-990e-445e-925b-95d98d357f99\DDCMP:/
Programme example
You can use the following programme example as a basis for creating a batch file, taking into account the syntax and the programme path:
@echo off
goto :EndOfComment
==========================================================
This batch file starts the EASY Starter 1.14
and inserts 1 online device over the connection 'OPC Diagnostics Server'.
Prerequisites:
The device must be connected to the PC via one of the following adapters:
Diagnosis adapter E94AZUS
USB Module i5MADU0000000S
How to specify the address of the device:
If a single adapter is plugged to the PC, just specify 'DDCMP:/'.
If several adapters are plugged to the PC, specify 'DDCMP:/HW'
followed by the hardware serial number of the adapter to be used,
followed by another '/', e.g. 'DDCMP:/HW123/'.
==========================================================
EndOfComment
start /d "<programme path>" MaintenanceTool.exe -Connection 85736b63-990e-445e-925b-95d98d357f99\DDCMP:/