Create IoT configuration with selected parameters

Prerequisite:

Ticking the "IoT configuration" box causes an additional IoT configuration tab to be displayed for the offline devices entered in the device list.

You can create the configuration on this tab.

If you want to configure several devices, save the configuration files of all devices to be provided by the "Lenze OPC UA Server" in one directory.

  • How to create the IoT configuration with selected parameters for "Lenze OPC UA Server":

  1. In the device list , select the offline device for which an IoT configuration is to be created.

  2. Select the IoT Configuration tab for this offline device.

    • An additional dialogue box with a tree structure is displayed next to the parameter list.

  3. Select the upper root node of the displayed tree.

  4. Select "OPC-UA" below the dialogue field.

    • The selection depends on what you want to create a configuration for.

  5. Select the Topic list element in the tree.

  6. Select the Add button.

    • A dialogue of the same name opens in which the name of a topic can be entered.

  7. Assign a name to the topic.

  8. Press the OK button.

    • The topic is entered in the tree and is selected.

  9. Select the required parameters from the parameter list displayed.

  10. Add to the selected topic using the arrow button.

  11. Press the Save button in the toolbar of the IoT Configuration tab.

    • An input window opens, prompting you to enter a name in a directory of your choice.

  12. Press the Save button.

    • The file is saved with the file type *.lia .

The creation of a configuration file is now complete.