L_TS2P_scAP_ElectronicGearboxBase

Structure of the access points

The access points (AP) can be used to influence signals. In the initial state, the access points do not have any effect.

Each access point acts as an alternative branch and is activated via an OR operation or a switch.

Designator

Data type

Description

AP_xGearingNumerator

BOOL

Enabling of the AP_dwGearingNumerator access point

TRUE

The access point overwrites the values at the access point in the signal flow.

Here the coupling factor in the scPar.dwGearingNumerator parameter becomes ineffective.

AP_dwGearingNumerator

LREAL

Active coupling factor for the Y axis

The setting of the parameter is effective in the "unit coupling" mode ( scPar.eCouplingMode = 0).

The coupling factor can also be modified cyclically in the clutched-in state.

AP_xGearingDenominator

BOOL

Enabling of the AP_dwGearingDenominator access point

TRUE

The access point overwrites the values at the access point in the signal flow.

Here the coupling factor in the scPar.dwGearingDenominator parameter becomes ineffective.

AP_dwGearingDenominator

LREAL

Active coupling factor for the X axis

The setting of the parameter is effective in the "unit coupling" mode ( scPar.eCouplingMode = 0).

The coupling factor can also be modified cyclically in the clutched-in state.