Synchronism with basic speed

Starting from a basic speed, the clutch function synchronizes the speed of the slave axis to the speed of the master axis without a step change.

Preconditions

  • The technology module is in an error-free state.

  • The drive is enabled ( xReadyForMotion = TRUE).

  • The slave and master axes are uncoupled ( xSyncIn = FALSE).

Execution

Synchronism with basic speed is active as soon as the lrSetBaseVel input takes on a non-zero value.

Immediately after the controller has been enabled, the slave axis moves by means of S-rounding at the basic speed specified as per the lrSetBaseVel input. The technology module changes to the "BASEVELOCITY" state. From this state, the speed of the slave axis can be synchronized to the master speed of the master axis via the clutch function.

For the clutch-in/declutch process, the acceleration, deceleration and clutch jerk are specified via parameters ( scPar.lrSyncAcc, . scPar.lrSyncDec, scPar.lrSyncJerk ).

Clutch-in starts at any position when the xSyncIn input is set to TRUE.

During the coupling process, the xAccDecSync output = TRUE. If there is synchronicity (clutch closed), the xSynchronized output = TRUE.

When declutching by means of xSyncIn = FALSE, the slave axis decelerates to the basic speed lrSetBaseVel as per the scPar.lrSyncDec parameter. When the basic speed is activated, the xBaseVelocityActive output is set to TRUE.

Inputs relevant for the function

  • lrSetBaseVel , initial value: 0 unit/s

  • xSyncIn , initial value: FALSE

Outputs relevant for the function

  • xAccDecSync

  • xSynchronised

  • xBaseVelocityActive

Parameters relevant for the function

  • scPar.lrSyncAcc , initial value: 1 000 unit/s²

  • scPar.lrSyncDcc , initial value: 1 000 unit/s²

  • scPar.lrSyncJerk , initial value: 1 000 000 unit/s³

Example

Clutch-in and declutch process with slave axis basic speed (lrSetBaseVel = 50)

No.

xSyncIn

xAccDecSync

xSynchronised

xBaseVelocityActive

eTMState

Info

1

FALSE

FALSE äTRUE

FALSE

FALSE äTRUE

STANDBY➔ACC_DEC_SYNC

The slave axis accelerates from standstill to a basic speed of 50 unit/s.

2

FALSE

TRUEæFALSE

FALSE

TRUE

ACC_DEC_SYNC➔BASEVELOCITY

The slave axis moves at a constant basic speed.

3

FALSE äTRUE

FALSE äTRUE

FALSE

TRUE æFALSE

BASEVELOCITY➔ACC_DEC_SYNC

The axis synchronizes to the speed of the master axis.

4

TRUEæFALSE

TRUE æFALSE

FALSE äTRUE

FALSE

ACC_DEC_SYNC➔SYNCHRONIZED

The axis moves synchronously to the master axis.

5

TRUE

FALSE äTRUE

TRUE æFALSE

FALSE

SYNCHRONIZED➔ACC_DEC_SYNC

The coupling to the master axis is released and the slave axis decelerates to the basic speed.

6

FALSE

TRUE æFALSE

FALSE

FALSE äTRUE

ACC_DEC_SYNC➔BASEVELOCITY

The slave axis moves at a constant basic speed.

7

FALSE

FALSE äTRUE

FALSE

TRUE

BASEVELOCITY➔ACC_DEC_SYNC

The slave axis decelerates to standstill.

8

FALSE

TRUEæFALSE

FALSE

TRUEæFALSE

ACC_DEC_SYNC➔STANDBY

Standstill