File transfer with monitored device-internal programming via Ethernet

A firmware file is written to a memory area of the inverter. The device does not need to be set to a special boot mode for this. To complete the transfer, the transfer of the transferred firmware can be started by a device command (parameter access). The progress and the result (status) of the device-internal firmware transfer can be determined by parameter accesses.

Command line "FTP" download

OSLoader.exe /8400batch <firmware> <IPv4> <FTP user> <FTP password> <log>

OSLoader.exe /i500batch <firmware> <IPv4> <FTP user> <FTP password> <log>

8400batch / i500batch

Keyword to start a download to an 8400 / i5xx target system

firmware

lpk file containing the firmware to be loaded

IPv4

IP address via which the target system can be reached via TCP/IP

FTP user

User' when configuring the FTP connection

FTP password

Password' when configuring the FTP connection

log

Log file for the started download

Command line "SFTP" download

OSLoader.exe /i900batch <firmware> <IPv4> <log>

OSLoader.exe /i750batch <firmware> <IPv4> <log>

i900batch/ i750batch

Keyword to start a download to an i9xx/ i750 target system

firmware

lpk file containing the firmware to be loaded

IPv4

IP address via which the target system can be reached via TCP / IP

log

Log file for the started download

Command line "OPC UA" download

OSLoader.exe /c500batch <firmware> <IPv4> <log> <opt. username> <opt. password>

c500batch

Keyword to start a download to an c5x0 / c4x0 target system

firmware

lpk file containing the firmware to be loaded

IPv4

IP address via which the target system can be reached via TCP / IP

log

Log file for the started download

Username (optional)

Credentials: User (if enabled on device)

Password (optional)

Credentials: Passwort (if enabled on device)

Command line "EASY TCP/IP" download

OSLoader.exe /i500motecBatch <firmware> <IPv4> <log>

i500motecBatch

Keyword to start a download to a i5x0motec target system

firmware

lpk file containing the firmware to be loaded

IPv4

IP address via which the target system can be reached via TCP/IP

log

Log file for the started download