L_TS2P_scSF_FlexCamState
Structure of the signal flow
The contents of the L_TS2P_scSF_FlexCamState structure are read-only and offer a practical diagnostics option within the signal flow (Signal flow diagram).
|
Designator Data type |
Description |
|
|---|---|---|
|
MP_lrSetMasterPos LREAL |
Setpoint position of the master axis. The position is read directly from the AxisRef.
|
|
|
MP_lrSetSlavePos LREAL |
Setpoint position of the slave axis. The position is read directly from the AxisRef.
|
|
|
MP_lrConvertMasterToXPos LREAL |
Calculated position of the x axis. This position results from the position of the master axis as well as the slave offset and slave scaling factor.
|
|
|
MP_lrCamProfilerPosOut LREAL |
Y position from the cam generator
|
|
|
MP_lrConvertYToSlavePos LREAL |
Resulting position of the slave axis after the clutch function. This position results from the position of the y axis as well as the master offset and the master scaling factor.
|
|
|
MP_lrSetXPos LREAL |
Position of the x axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrSetXVel LREAL |
Speed of the x axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrSetXAcc LREAL |
Acceleration of the x axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrSetYPos LREAL |
Position of the y axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrActYPos |
Current position of the y axis Here the value is converted from the current speed of the slave axis to the y axis. Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrSetYVel LREAL |
Speed of the y axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrActYVel |
Current speed of the y axis Here the value is converted from the current speed of the slave axis into the y axis. Note: T his output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_lrSetYAcc LREAL |
Acceleration of the y axis as per the cam Note: This output only shows valid values in the "CAMMING" state. In other states, it is deactivated (value = 0).
|
|
|
MP_xEndOfProfPositive BOOL |
Last cycle in the current cam profile when the master speed is positive.
|
|
|
FALSE äTRUE |
The x-curve position jumps to the next or previous profile pulse. |
|
|
FALSE |
No cycle transition has occurred. |
|
|
MP_xEndOfProfNegative BOOL |
Last cycle in the current cam profile when the master speed is negative.
|
|
|
FALSE äTRUE |
The x-curve position jumps to the next or previous profile pulse. |
|
|
FALSE |
No cycle transition has occurred. |
|
|
MP_lrSlaveMaxPos LREAL |
Maximum position of the slave axis
This value is determined from the cam applied at the TM. The parameters scPar.lrMasterMaxVel (master speed) and scPar.lrMasterMaxAcc (master acceleration) are included in the calculation. It is calculated if:
|
|
|
MP_lrSlaveMaxPos LREAL |
Minimum position of the slave axis
This value is determined from the cam applied at the TM. The parameters scPar.lrMasterMaxVel (master speed) and scPar.lrMasterMaxAcc (master acceleration) are included in the calculation. It is calculated if:
|
|
|
MP_lrSlaveMaxVel LREAL |
Maximum velocity of the slave axis
This value is determined from the cam applied at the TM. The parameters scPar.lrMasterMaxVel (master speed) and scPar.lrMasterMaxAcc (master acceleration) are included in the calculation. It is calculated if:
|
|
|
MP_lrSlaveMaxAcc LREAL |
Maximum acceleration of the slave axis
This value is determined from the cam applied at the TM. The parameters scPar.lrMasterMaxVel (master speed) and scPar.lrMasterMaxAcc (master acceleration) are included in the calculation. It is calculated if:
|
|
|
MP_xInternalControlActive BOOL |
The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored. |
|