Inputs

Basic functions

(missing or bad snippet)

Technology functions

Designator

Data type

Description

scPar

L_TS2P_scPar_FlexCamState

The parameter structure contains the parameters of the TM.

Axis

AXIS_REF

Reference to the axis

MasterValues

L_MC1P_IAXIS_REF_MASTERVALUES

Connection for the master values (master axis)

scAccessPoints

L_TS2P_scAP_FlexCamState

Structure of the access points

The access points can be used to influence the signal flow or TM functions.

xSyncIn

BOOL

Synchronize the slave axis to the position resulting from the cam.

The input is level-controlled and evaluates a high level.

  • Parameter:eSyncMode coupling mode

  • Initial value: FALSE

TRUE

Clutching in to the cam

FALSE

Declutching from the cam

xCamChangeInstant

BOOL

The input is edge-controlled and evaluates the rising edge.

  • Changing the cam

  • Specify the switching sequence for cams

FALSE รคTRUE

A changeover from the currently used cam to the newly created cam takes place in the current clock cycle.

lrSetOffsetPosX

LREAL

Master axis position offset

The resulting x position of the cam results from adding the master axis position to the offset as per this input.

  • Offset for the master and slave axis

  • Unit: Units

  • Initial value: 0

lrSetOffsetPosY

LREAL

Slave axis position offset

The resulting position of the slave axis is obtained by adding the y position to the offset as per this input.

  • Offset for the master and slave axis

  • Unit: Units

  • Initial value: 0

lrSetScalingX

LREAL

Scaling factor of the master axis

The resulting x position of the cam is obtained by multiplying the master axis position by the scaling factor as per this input.

  • Offset for the master and slave axis

  • Value range: 0 to infinity

  • Initial value: 1

lrSetScalingY

LREAL

Scaling factor of the slave axis

The resulting extended/compressed y setpoint position is obtained by multiplying the y value of the cam by the scaling factor as per this input.

  • Offset for the master and slave axis

  • Value range: 0 to infinity

  • Initial value: 1

CamTable1

MC_CAM_REF

Reference to cam 1

CamTable2

MC_CAM_REF

Reference to cam 2

CamTable3

MC_CAM_REF

Reference to cam 3

CamTable4

MC_CAM_REF

Reference to cam 4

wSetCamTable

WORD

Selection of a cam

  • Specify the switching sequence for cams

  • Initial value: 1

1

Cam 1

2

Cam 2

3

Cam 3

4

Cam 4

xCamSequencer

BOOL

TRUE

Activate switching sequence for cams.

Cams are executed according to the switching sequence in the eCamSequenceMode parameter.

  • Specify the switching sequence for cams