State machine

State machine of the technology module

Œ

A transition to the "ERROR" or "STOP" state is possible.

0

In the "STANDBY" state, xEnableOperation must be set to TRUE.

1

In the "ERROR" state, xResetError must be set to TRUE for acknowledging and resetting the errors.

2

The "EXTERNAL" state is set if a function generates setpoints outside the technology module for the axis connected, e.g. MC_CamIn, MC_MoveAbsolute .

3

eAxisState = "STANDSTILL"

States of the eTMState output (L_TB2P_States)

ACC_DEC_SYNC

Position the axis on the cam output

Nr.

L_TB2P_States

Beschreibung

-1

DISABLED

Technology module deactivated

0

STANDBY

Technology module is on standby

1

STOP

Stop/Halt active

2

HOMING

Homing active

3

JOGGING

Manual jog active

4

MOVEVEL

Continuous travel with a defined velocity active

5

MOVEABS

Absolute positioning active

6

MOVEREL

Relative positioning active

7

EXTERNAL

An external function generates setpoints for the connected axis

8

ERROR

System fault

30

33

CAMMING

Clutch with cam active

210

MOVE_TO_PARK_POS

Position the axis in the park position

212

IDENTIFICATION

Identification of the X-curve position

1000

SYSTEMFAULT

Error state