L_TS2P_scSF_FlyingSawState

Structure of the signal flow

The contents of the structure are read-only and offer a practical diagnostics option within the signal flow.

Designator

Data type

Description

MP_lrSetMasterPos

LREAL

Setpoint position of the master axis.

  • Unit: Units

MP_lrSetSlavePos

LREAL

Setpoint position of the slave axis.

  • Unit: Units

MP_lrTotalCuttingLength

LREAL

Total cutting length.

  • Unit: Units

MP_xPosSynchronised

BOOL

TRUE

The set values of the master axis and the slave axis are synchronised with each other.

MP_lrCutLengthProcessed

LREAL

Distance travelled from the cut. Value range, 0 to the cutting length

  • Unit: Units

MP_xMarkReceived

BOOL

New mark detected.

MP_wMarkIndex

WORD

Number of marks stored in the marker stack

MP_xMarkStackEmpty

BOOL

TRUE

There is no longer a marker on the marker stack.

MP_xMarkStackFull

BOOL

TRUE

The marker stack is completely filled.

The next recognised marker overwrites the oldest registered marker on the marker stack.

MP_lrStackMarkPos

LREAL

Position of the marker currently being returned by the marker stack.

  • Unit: units

MP_xMasterVelInWindow

BOOL

TRUE

The speed of the master value is within the tolerance limit scPar.lrToleranceMasterVelInWindow.

TRUE: The optimised motion for the return movement is active and the speed of the master value is within the limit.

FALSE: the optimised motion is inactive because:

  • No return motion is active or,

  • the speed of the master value scPar.lrToleranceMasterVelInWindow has left during the return motion

MP_xSlavePosUpperLimit

BOOL

TRUE

The position of the saw carriage is above the upper limit of the travelling range.

MP_xSlavePosLowerLimit

BOOL

TRUE

The position of the saw carriage is below the lower limit of the travelling range.

MP_xInternalControlActive

BOOL

The technology module is currently controlled by the InternalControl functionality (visualization template). Commands from the tm interface are ignored.