Structure of the signal flow

L_TF2P_scSF_FollowSetValues

The contents of the structure are read-only and offer a practical diagnostics option within the signal flow.

Signal flow diagrams

Designator

Data type

Description

MP_lrSetVelocityFiltered

LREAL

The setpoint speed after the PT1 filter.

  • Unit: units/s

MP_lrSetTorqueFiltered

LREAL

The setpoint torque after the PT1 filter.

  • Unit: Nm

MP_xInternalControlActive

BOOL

The technology module is currently controlled via the InternalControl function (visualization template). Commands sent via the tm interface are ignored.