Read and forward severity levels
Two topological constellations are often found in modular machines.
Constellation 1:
A central machine module controls two further subordinate modules, which in turn control a further two machine modules.
Structure of the programming:
-
As soon as a subordinate module reports an error, all higher-level modules and all modules in parallel branches should react.
-
In the example in the figure above, the "MM30" module triggers the ERROR response. The ERROR response is also triggered for all other modules.
Constellation 2:
A central machine module controls two further subordinate modules, which in turn control a further two machine modules.
Structure of the programming:
-
As soon as a subordinate module reports an error, all higher-level modules should react.
-
In the example in the figure above, the "MM30" module triggers the ERROR response. The ERROR reaction is also triggered for all higher-level modules. However, the modules in the parallel branch should not react to this.
This requirement can be easily programmed with the following two function blocks:
-
L_IE1P_ReadActualSeverity:
The FB reads out the error of the selected module with the highest severity.
-
L_IE1P_ForwardSeverity:
The FB forwards the severity level to the superimposed modules.
TIP: Due to the power of this function, there is a dedicated explanatory video (FAST_TeachMe_ForwardSeverity)