L_IF1P_ConnectDevice

This FB can be used to connect a function of the device tree (axis or encoder) to an ECAT slave or an I/O module.

The execution can take several cycles.

 

 

 

L_IF1P_ConnectDevice

 

 

 

BOOL

–

 

xExecute

xBusy

 

–

BOOL

L_IMHP_IModuleHandler

–

 

FunctionModuleHandler

xDone

 

–

BOOL

L_IMHP_IModuleHandler

–

 

DeviceModulehandler

xError

 

–

BOOL

UINT

–

 

uiSubDevice

eErrorId

 

–

L_IE1P_Error

BOOL

–

 

xDisconnectExistingConnection

 

 

 

 

L_IF1P_DisconnectMode

–

 

eDisconnectMode

 

 

 

 

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Info/adjustment options

xExecute

BOOL

FALSE->TRUE Start execution of the FB and establish connection.

FunctionModuleHandler

L_IMHP_IModuleHandler

Module handler of the function that is to be connected.

DeviceModulehandler

L_IMHP_IModuleHandler

Module handler of the device that is to be connected to the function.

uiSubDevice

UINT

Submodule of a device with several submodules to be connected

Default: uiSubdevice = 0

Example i700 double axis:

Axis A: uiSubdevice = 1

Axis B: uiSubdevice = 2

xDisconnectExistingConnection

BOOL

 

TRUE

If a function is to be connected to a device that is already connected to another function, this connection is disconnected.

FALSE

If a function is to be connected to a device that is already connected to another function, an error is displayed.

eDisconnectMode

L_IF1P_DisconnectMode

Behavior of the function when the connection has been disconnected:

Virtual:

  • The axis is still calculated as a virtual axis.

Disable:

  • The axis is deactivated and no longer calculated.

Outputs

Name

Data type

Info/adjustment options

xBusy

BOOL

New connection is configured.

 

xDone

BOOL

The connection between the function and the specified device (e.g. EtherCat slave) has been set.

xError

BOOL

An error has occurred.

eErrorId

L_IE1P_Error

If xError = TRUE: Error number of the error that has occurred.