L_LA1P_TaElectronicGearbox

This FB provides the interface for controlling the "Electronic Gearbox" technology application of the i950.

 

 

 

L_LA1P_TaElectronicGearbox

 

 

 

L_LA1P_AXIS_REF

-

LogicAxis

xError

-

BOOL

BOOL

-

xControlSignalBit0

eErrorID

-

L_IE1P_Error

BOOL

-

xControlSignalBit1

xCommunicationOK

-

BOOL

BOOL

-

xActivateQspApplication

xReadyForOperation

-

BOOL

BOOL

-

xEnableOperation

xHomingActive

-

BOOL

BOOL

-

xControlSignalBit4

xOperationEnabled

-

BOOL

BOOL

-

xJogPositive

xDriveFault

-

BOOL

BOOL

-

xJogNegative

xDriveHomed

-

BOOL

BOOL

-

xFaultReset

xQspActive

-

BOOL

BOOL

-

xHalt

xJoggingBusy

-

BOOL

BOOL

-

xHomeExecute

xDriveWarning

-

BOOL

BOOL

-

xHomePosReset

xHaltBusy

-

BOOL

BOOL

-

xAbort

xStatusSignalBit9

-

BOOL

BOOL

-

xControlSignalBit12

xInVelocity

-

BOOL

BOOL

-

xControlSignalBit13

xAbortBusy

-

BOOL

BOOL

-

xReleaseBrakeManual

xStandstill

-

BOOL

BOOL

-

xControlSignalBit15

xDirectionInverted

-

BOOL

BOOL

-

xSyncIn

xBrakeReleased

-

BOOL

BOOL

-

xControlSignalBit17

xSTOActive

-

BOOL

BOOL

-

xControlSignalBit18

xSynchronised

-

BOOL

BOOL

-

xControlSignalBit19

xAccDecSync

-

BOOL

BOOL

-

xTrimPositive

xOffsetTrimmingActive

-

BOOL

BOOL

-

xTrimNegative

xBaseVelocityActive

-

BOOL

BOOL

-

xActivateExtTorqueLimit

xElectronicGearboxBusy

-

BOOL

BOOL

-

xActivateExtVelocityOffset

xStatusSignalBit21

-

BOOL

BOOL

-

xActivateExtBaseVelocity

xExtTorqueLimitActive

-

BOOL

BOOL

-

xVM_Continuous

xExtVelocityOffsetActive

-

BOOL

BOOL

-

xVM_Cycle

xExtBaseVelocityActive

-

BOOL

BOOL

-

xVM_LoadPosition

xVM_Busy

-

BOOL

BOOL

-

xVM_JogPositive

xVM_InTarget

-

BOOL

BOOL

-

xVM_JogNegative

xVM_Synchronised

-

BOOL

BOOL

-

xVM_Halt

xVM_AccDecSync

-

BOOL

BOOL

-

xVM_DeactivateExtMaster

xStatusSignalBit29

-

BOOL

DWORD

-

dwFreeControlword01

xStatusSignalBit30

-

BOOL

LREAL

-

lrVM_SetVelocity

xVM_ExtMasterValuesInactive

-

BOOL

LREAL

-

lrExtVelocityOffset

dwStatusSignalsLimiter

-

DWORD

DWORD

-

dwFreeControlword04

lrActualVelocity

-

LREAL

DWORD

-

dwFreeControlword05

dwFreeStatusword03

-

DWORD

LREAL

-

lrExtBaseVelocity

dwErrorCode

-

DWORD

LREAL

-

lrExtTorqueLimit

lrActualTorque

-

LREAL

dwMonitoringSignal1

-

DWORD

dwMonitoringSignal2

-

DWORD

 

 

 

 

 

 

 

 

Inputs/Outputs

Name

Data type

Description

LogicAxis

L_ LA1P _AXIS_REF

Reference to the axis that is to be controlled and monitored

Inputs

Name

Data type

Description

xControlSignalBit x

BOOL

TRUE

This bit can be assigned to optional functions

xActivateQspApplication

BOOL

TRUE

Rotating drive is stopped via the QSP ramp. The drive remains in closed-loop control at standstill.

xEnableOperation

BOOL

TRUE

Drive is enabled. At low level, a rotating drive is stopped via the FAST Stop ramp and disabled at standstill.

xJogPositive

BOOL

TRUE

The drive moves in the positive direction in manual mode. The positive software limit switch is observed.

xJogNegative

BOOL

TRUE

The drive moves in negative direction in manual mode. The negative software limit switch is observed.

xFaultReset

BOOL

FALSE รค TRUE

Errors are reset if the cause has been eliminated.

xHalt

BOOL

FALSE รค TRUE

The active movement is aborted and the axis is brought to a standstill via the halt ramp.

xHomeExecute

BOOL

FALSE รค TRUE

A reference run is started by this bit

xHomePosReset

BOOL

FALSE รค TRUE

This bit resets the reference position

xAbort

BOOL

FALSE รค TRUE

Active movement is aborted and axis is guided to standstill via the active profile deceleration. A change to the "STOP" state takes place. The deceleration ramp can be canceled by assigning a new movement (e.g. xMoveVelExecute).

xReleaseBrakeManual

BOOL

TRUE

Holding brake is released

xSyncIn

BOOL

TRUE

Synchronization of the slave axis to the master axis

xTrimPositive

BOOL

TRUE

Trim position in the positive direction.

xTrimNegative

BOOL

TRUE

Trim position in the negative direction.

xActivateExtTorqueLimit

BOOL

TRUE

With this bit the external torque limits are switched on. Otherwise the internal torque limits apply

xActivateExtVelocityOffset

BOOL

TRUE

This bit is used to add an external offset to the speed setpoint.

xActivateExtBaseVelocity

BOOL

TRUE

With this bit the external basic speed is used and not the parameter value (0x5041:043)

xVM_Continuous

BOOL

TRUE

Perform continuous operation of the virtual master.

xVM_Cycle

BOOL

FALSE รค TRUE

Execute single-cycle operation of the virtual master.

xVM_LoadPosition

BOOL

TRUE

Load start position of the virtual master axis.
โ€ข This function can also be executed when the axis is locked or when xVM_Halt = TRUE.
โ€ข This function cannot be executed during position synchronization.

xVM_JogPositive

BOOL

TRUE

Move virtual master in positive direction (virtual master manual movement).

xVM_JogNegative

BOOL

TRUE

Move virtual master in negative direction (virtual master manual movement).

xVM_Halt

BOOL

FALSE รค TRUE

Abort active movement of the virtual master and bring the axis to a standstill with the deceleration defined via the Halt parameter

xVM_DeactivateExtMaster

BOOL

TRUE

External master values are deactivated. The virtual master is used as the master value source. Jump-free changeover of couplings.

dwFreeControlword x

DWORD

This double word can be assigned to optional functions

lrVM_SetVelocity

LREAL

The value of the setpoint velocity of the virtual master is specified in unit/s and has 4 decimal places.

lrExtVelocityOffset

LREAL

The value of the external velocity offset is specified in unit/s and has 4 decimal places

lrExtBaseVelocity

LREAL

The value of the external basic speed is specified in unit/s and has 4 decimal places.

lrExtTorqueLimit

LREAL

The value of the external torque limit is specified in %, related to the rated motor torque 0x6076:0 and has 2 decimal places.

Outputs

Name

Data type

Description

xError

BOOL

TRUE

The function block has an error

eErrorID

L_IE1P_Error

Error number

xCommunicationOK

BOOL

TRUE

Communication with the drive is ok

xReadyForOperation

BOOL

TRUE

Axis Ready to switch on

xHomingActive

BOOL

TRUE

Homing is active

xOperationEnabled

BOOL

TRUE

Axis is released

xDriveFault

BOOL

TRUE

Drive fault is active

xDriveHomed

BOOL

TRUE

Drive is homed

xQspActive

BOOL

TRUE

Quickstop was triggered

xJoggingBusy

BOOL

TRUE

Manual operation is active

xDriveWarning

BOOL

TRUE

Drive warning is active

xHaltBusy

BOOL

TRUE

Halt is active

xStatusSignalBit x

BOOL

TRUE

This bit can be assigned to optional functions

xInVelocity

BOOL

TRUE

Target velocity was reached for the first time

xAbortBusy

BOOL

TRUE

The activated function is canceled.

xStandstill

BOOL

TRUE

Drive is at standstill

xDirectionInverted

BOOL

TRUE

Direction of rotation is inverted

xBrakeReleased

BOOL

TRUE

Holding brake is released

xSTOActive

BOOL

TRUE

Safe Torque Off is active

xSynchronised

BOOL

TRUE

The axis is synchronized with the master axis.

xAccDecSync

BOOL

TRUE

Velocity clutch active

xOffsetTrimmingActive

BOOL

TRUE

Velocity offset and/or trim active.

xBaseVelocityActive

BOOL

TRUE

Base velocity active

xElectronicGearboxBusy

BOOL

TRUE

The coupling function is active. It is synchronized up or down or the axis is synchronized.

xExtTorqueLimitActive

BOOL

TRUE

External torque limit is active

xExtVelocityOffsetActive

BOOL

TRUE

External velocity offset is active

xExtBaseVelocityActive

BOOL

TRUE

External base velocity is active

xVM_Busy

BOOL

TRUE

Virtual Master active

xVM_InTarget

BOOL

TRUE

Virtual Master axis has reached the target position (Virtual Master Target Position 0x5046:002) and is at standstill.

xVM_Synchronised

BOOL

TRUE

The virtual master axis is velocity and position synchronous to the external control values (system bus or application feedback (B) ).

xVM_AccDecSync

BOOL

TRUE

The synchronization function is active. The virtual master axis is coupled to or decoupled from the external master values (system bus or application feedback (B) ).

xVM_ExtMasterValuesInactive

BOOL

TRUE

External master (system bus or application feedback (B) ) is deactivated

dwStatusSignalsLimiter

DWORD

Status signals of the internal limiter FB (L_MC1P_Limiter)

lrActualVelocity

LREAL

Actual velocity

dwFreeStatusword x

DWORD

This double word can be assigned to optional functions

dwErrorCode

DWORD

Errorcode

lrActualTorque

LREAL

Actual torque

dwMonitoringSignal x

DWORD

Configured monitoring signal