L_IOCP_Variable
Structure to address an IEC variable by the OPC UA Client. The value of this IEC Variable will be written to an OPC UA Server variable node in case of the function block UA_WriteList. A UA Server node attribute will be written to the IEC variable in case of the function block UA_ReadList. The IEC and OPC UA variable type definition must fit together, see L_IOCP_VariableDataType.
|
Name Data type |
Information/possible settings |
|---|---|
|
NodeDataType L_IOCP_VariableDataType |
Data type of the IEC variable to be accessed. |
|
pData POINTER to BYTE |
Address of the IEC variable |
|
udiDataSize UDINT |
Size of the IEC variable |
Note:
-
Currently simple variables of L_IOCP_VariableDataType type definitions are supported.
-
Up to 4k of data could be processed in a single service call (e.g. UA_WriteList).