Abort and termination of a path (Abort)
Prerequisite
-
The axes are enabled (xReadyForMotion = TRUE).
-
A web is run
Execution
With a rising edge (FALSEรคTRUE) at the xGroupAbort input, the current movement of the axis group is interrupted and brought to a standstill with the deceleration ramp from the path planning (following the travel profile).
The technology module changes to the STOP state (display at the eTMState output). After reaching standstill, the xPathHold output is set = TRUE. This indicates that the current position in the profile has been noted so that the path can be continued at this point.
The technology module changes to the STANDBY state as soon as the standstill is reached and the input xGroupAbort = FALSE is set. The TM may continue the path or calculate and execute a new path.
The railroad is to be continued at its stopping point
If the output xPathHold = TRUE is active, the "Finish" function can be activated. In this case, the marked path is run to the end.
The driving profile is to be canceled
With the new command or functions like Move xMoveLinAbsExecute the held path is discarded. The status xPathHold = FALSE is set.
Parameters to be set
The parameters for the xGroupAbort are taken from the current profile.