L_MC4P_ToolControl
This FB can be used to generate a switching pulse for a selected tool. The switching times for switching on and off are defined with the tool in the axis group (switch-on time, switch-off time).
-
The path and tool parameters are not influenced by the FB.
-
Several FBs can be operated in parallel for different tools.
-
For NoTool the switching times = 0.
-
The xPulseOn or xPulseOff switching signals are set to TRUE for a clock pulse if the time until the target position is reached corresponds to the tool parameters Switch On Time or Switch off Time.
|
Note!
Operation is only possible with the L_TX2P_PickAndPlaceBase technology module. |
|
|
|
|
L_MC4P_ToolControl |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
AXES_GROUP_KIN |
- |
|
AxesGroup |
xBusy |
|
- |
BOOL |
|
BOOL |
- |
|
xExecute |
xError |
|
- |
BOOL |
|
L_MC4P_ToolSystem |
- |
|
diParameterNumber |
eErrorID |
|
- |
L_IE1P_Error |
|
|
|
|
|
xPulseOn |
|
- |
BOOL |
|
xPulseOff |
|
BOOL |
|||||
|
lrTimeToPulse |
|
LREAL |
|||||
|
|
|
|
|
|
|
|
|
Inputs
|
Name Data type |
Information/possible settings |
|
|---|---|---|
|
AxesGroup AXES_GROUP_KIN |
Axis Group Reference |
|
|
xEnable BOOL |
TRUE |
Start execution of the FB. |
|
eToolSystem L_MC4P_ToolSystem |
Tool in which the switching times are defined
|
|
Outputs
|
Name Data type |
Information/possible settings |
|
|---|---|---|
|
xBusy BOOL |
TRUE |
Processing in progress |
|
xError BOOL |
TRUE |
An error has occurred. For details see eErrorID |
|
eErrorID L_IE1P_Error |
If xError = TRUE: Error number for the error that occurred. FAST Technology Modules Reference Manual: Here you will find information about error or warning messages. |
|
|
xPulseOn BOOL |
TRUE |
Switch on tool |
|
xPulseOff BOOL |
TRUE |
Switch off tool |
|
lrTimeToPulse LREAL |
Duration until the next switching pulse in s |
|