Outputs

Basic functions

Designator

Data type

Description

xReadyForOperation

BOOL

The axis is faultless.

The DC bus voltage is available.

"Safe Torque Off" (STO) is not active.

xOperationEnabled

BOOL

The axis is enabled.

The brake is released.

xReadyForMotion

BOOL

The axis is enabled and faultless.

The brake is released.

xError

BOOL

TRUE

There is an error in the technology module.

xWarning

BOOL

TRUE

There is a warning in the technology module.

eErrorID

L_IE1P_Error

ID of the error or warning message if xError = TRUE or xWarning = TRUE.

Here you can find information on error and warning messages: L_IE1P_Error

xSTOActive

BOOL

TRUE

"Safe Torque Off" (STO) was enabled and is active.

The axis is torque-free and the inverter is inhibited.

xQSPActive

BOOL

TRUE

The xQSPApplication input is set to TRUE.

The technology module is in the "STOP" state, the axis is brought to a standstill.

The output is reset as soon as the axis is at a standstill.

xAbortBusy

BOOL

TRUE

The function activated is aborted by the xAbort input.

xAbortDone

BOOL

TRUE

The activated function is aborted by the xAbort input.

xJoggingBusy

BOOL

TRUE

The manual jog function is active.

The technology module is in the "JOGGING" state.

xHomingBusy

BOOL

TRUE

Homing is executed.

The technology module is in the "HOMING" state.

xHomingDone

BOOL

TRUE

Homing has been completed successfully.

xIsHomed

BOOL

TRUE

The axis has been referenced ("Reference known").

xIsHomed may only be evaluated when the xAxisAvailable status is reported.

eTMState

L_TB2P_States

Current state of the technology module

scStatusBasicMotion

L_TB2P_scStatusBasicMotion

Structure of the status data of the function block

lrActVel

LREAL

Current velocity

  • Unit: units/s

lrSetVelOut

LREAL

Setpoint speed

  • Unit: units/s

lrActPos

LREAL

Actual position

  • Unit: units

lrSetPosOut

LREAL

Setpoint position

  • Unit: units

lrActFollowingError

LREAL

Current following error

  • Unit: units

Technology functions

Identifier

Data type

Description

scSignalFlow

L_TF2P_scSF_SpeedControlBase

Variables summarised in a structure that can be used to tap into measurement points in the signal flow of the technology module.

xSpeedControlBusy

BOOL

TRUE

Speed mode is active.

xExtAccDecJerkActive

BOOL

TRUE

The xUseExtAccDecJerk input is TRUE. The acceleration and deceleration values are accepted by the lrExtAcc , lrExtDec and lrExtJerk inputs.

xOffsetVelActive

BOOL

TRUE

The offset set at the lrSetOffsetVel input is non-zero.

xProfileVelActive

BOOL

TRUE

The setpoint speed is not accepted by the lrSetVel input, but from the profile data.

wActiveProfile

WORD

Number of the current speed profile

0: profile 0

1: profile 1

...

15: profile 15