L_TV2P_scAP_StackerCraneAxisControlBase
Structure of the points of attack
|
Identifier |
Description |
|
|---|---|---|
|
AP_eOscCompExecutionIndex |
Execution index A maximum of two setpoint manipulating FBs can be connected to one axis. The call sequence is defined via this input. Selection:
|
|
|
AP_xOscCompIgnoreFilterOnStop |
Consideration of the "Oscillation Compensation" function during the stop. |
|
|
TRUE |
Deactivation of the filter in the state Stopping Deactivating the filter is useful if the filter mechanism introduces a large dead time into the system, which would significantly delay the stop of the axis. |
|
|
FALSE |
The filter function Vibration compensation is active for the stop function. |
|
|
AP_xOscCompManipulateTroque |
Filtering of an additive feedforward torque. |
|
|
TRUE |
The additive pilot torque is filtered. |
|
|
AP_xOscCompAmpRatio |
Release of the AP_lrOscCompAmpRatio attack point. |
|
|
TRUE |
The attack point overwrites the values at the access point in the signal flow. |
|
|
AP_lrOscCompAmpRatio |
Ratio of two successive amplitudes.
|
|
|
AP_xOscCompEigenFreq |
Release of the attack point AP_lrOscCompEigenFreq. |
|
|
TRUE |
The attack point overwrites the values at the access point in the signal flow. |
|
|
AP_lrOscCompEigenFreq |
Natural frequency of the damped system in [Hz].
|
|
|
AP_xOscCompPosScaled |
Release of the AP_lrOscCompPosScaled attack point. |
|
|
|
TRUE |
The attack point overwrites the values at the access point in the signal flow. |
|
AP_lrOscCompPosScaled |
Specification of the scaled position for vibration compensation.
|
|