L_TV2P_scAP_StackerCraneAxisControlBase

Structure of the points of attack

Identifier

Description

AP_eOscCompExecutionIndex

Execution index

A maximum of two setpoint manipulating FBs can be connected to one axis. The call sequence is defined via this input.

Selection:

  • L_MC1P_ExecutionIndex.First := 1

  • L_MC1P_ExecutionIndex.Second := 2

  • Initial value: 1

AP_xOscCompIgnoreFilterOnStop

Consideration of the "Oscillation Compensation" function during the stop.

TRUE

Deactivation of the filter in the state Stopping

Deactivating the filter is useful if the filter mechanism introduces a large dead time into the system, which would significantly delay the stop of the axis.

FALSE

The filter function Vibration compensation is active for the stop function.

AP_xOscCompManipulateTroque

Filtering of an additive feedforward torque.

TRUE

The additive pilot torque is filtered.

AP_xOscCompAmpRatio

Release of the AP_lrOscCompAmpRatio attack point.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrOscCompAmpRatio

Ratio of two successive amplitudes.

  • Value range: 0..1

  • Intial value: 1

AP_xOscCompEigenFreq

Release of the attack point AP_lrOscCompEigenFreq.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrOscCompEigenFreq

Natural frequency of the damped system in [Hz].

  • Value range: 0.4 ... 40

  • Intial value: 0

AP_xOscCompPosScaled

Release of the AP_lrOscCompPosScaled attack point.

 

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrOscCompPosScaled

Specification of the scaled position for vibration compensation.

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0 (0 %)