Inputs

Basic functions

Designator

Data type

Description

xEnable

BOOL

TRUE

The function block is activated.

FALSE

The function block is deactivated.

xEnableOperation

BOOL

TRUE

The axis is switched to the "ready for operation" state.

Controller enable is issued.

xResetError

BOOL

FALSEäTRUE

Reset axis error or software error.

xQSPApplication

BOOL

TRUE

The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.

  • The technology module remains in the "STOP" state as long as the quick stop is executed.

  • The function cannot be replaced by another function.

xAbort

BOOL

FALSEäTRUE

The active movement is cancelled and the axis is brought to a standstill profile deceleration (scPar.IrDec).

  • The state changes to "Stop".

The deceleration ramp can be aborted by commissioning of a new movement (e.g. xMoveVelExecute)

xJogPos

BOOL

TRUE

Traverse axis in positive direction (manual jog).

If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xJogNeg

BOOL

TRUE

Traverse axis in negative direction (manual jog).

If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xHomeExecute

BOOL

FALSEäTRUE

Start homing.

The function is aborted via the xHalt input.

lrOverride

LREAL

With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)

  • Value range: 0 ... 1.0

  • Initial value: 1.0

Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate.

scCtrlBasicMotion

L_TB2P_scCtrlBasicMotion

Structure input for controlling basic motion functions

Technology functions

Identifier

Data type

Description

scPar

L_TF2P_scPar_TablePositioningBase

Parameters of the technology module summarised in a structure.

Axis

AXIS_REF

Reference to the axis

scAccessPoints

L_TF2P_scPar_TablePositioningBase

Access points that are summarised in a structure and can be used to influence the signal flow or the functions of the technology module.

There are no access points available in this technology module.

wProfileNumber

WORD

Selection of the active travel profile

15 different travel profiles (1 - 15) can be selected.

No profile will be run if "0" is entered. A warning appears when starting

xExecutePositioning

BOOL

FALSE

ä

TRUE

The travel profile selected at the wProfileNumber input will be executed.

Restart by a renewed FALSEäTRUE edge:

During a running positioning process, another profile can be specified via the scPar.ascProfiles profile data structure that will be executed after a restart.

L_TF2P_scPar_TablePositioningBase

scTPRecData

L_MC1P_TpRecieveData

Touch probe structure input