Inputs
Basic functions
|
Designator Data type |
Description |
|
|---|---|---|
|
xEnable BOOL |
TRUE |
The function block is activated. |
|
FALSE |
The function block is deactivated. |
|
|
xEnableOperation BOOL |
TRUE |
The axis is switched to the "ready for operation" state. Controller enable is issued. |
|
xResetError BOOL |
FALSEäTRUE |
Reset axis error or software error. |
|
xQSPApplication BOOL |
TRUE |
The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.
|
|
xAbort BOOL |
FALSEäTRUE |
The active movement is cancelled and the axis is brought to a standstill profile deceleration (scPar.IrDec).
The deceleration ramp can be aborted by commissioning of a new movement (e.g. xMoveVelExecute) |
|
xJogPos BOOL |
TRUE |
Traverse axis in positive direction (manual jog). If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops. |
|
xJogNeg BOOL |
TRUE |
Traverse axis in negative direction (manual jog). If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops. |
|
xHomeExecute BOOL |
FALSEäTRUE |
Start homing. The function is aborted via the xHalt input. |
|
lrOverride LREAL |
With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)
Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate. |
|
|
scCtrlBasicMotion |
Structure input for controlling basic motion functions |
|
Technology functions
|
Identifier Data type |
Description |
|
|---|---|---|
|
scPar L_TF2P_scPar_TablePositioningBase |
Parameters of the technology module summarised in a structure. |
|
|
Axis AXIS_REF |
Reference to the axis |
|
|
scAccessPoints L_TF2P_scPar_TablePositioningBase |
Access points that are summarised in a structure and can be used to influence the signal flow or the functions of the technology module. There are no access points available in this technology module. |
|
|
wProfileNumber WORD |
Selection of the active travel profile 15 different travel profiles (1 - 15) can be selected. No profile will be run if "0" is entered. A warning appears when starting |
|
|
xExecutePositioning BOOL |
FALSE ä TRUE |
The travel profile selected at the wProfileNumber input will be executed. Restart by a renewed FALSEäTRUE edge: During a running positioning process, another profile can be specified via the scPar.ascProfiles profile data structure that will be executed after a restart.
|
|
scTPRecData L_MC1P_TpRecieveData |
Touch probe structure input |
|
L_TF2P_scPar_TablePositioningBase