Structure of the access points

L_TW2P_scAP_TraverserState

Signals can be influenced via the access points (AP). In the initial state, the access points have no effect.

Each access point acts as an alternative branch and is activated via an OR operation or a switch.

Identifier

Data type

Description

AP_xExternalMaster
Position

BOOL

Release of the attack point AP_lrExternalMasterPosition.

Initial value: FALSE

TRUE

The master position is not read from the master axis structure, but it is specified directly.

Attention:

The changeover is direct (immediate)

Incorrect use can lead to jerky movements of the traversing drive

AP_lrExternalMaster
Position

LREAL

External presetting of the master position.

The modulo value of the master is assumed to be 360.0° for one winding revolution.

  • Unit: degrees

  • Range: 0.0 ... 360.0

AP_xSyncInAngleLower

BOOL

Release of the attack point AP_lrSyncInAngleLower.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrSyncInAngleLower

LREAL

The parameter lrSyncInAngle (ramp angle) is used at the lower and upper reversal point.

AP_lrSyncInAngleLower specifies an alternative ramp angle for the lower reversal point.

AP_xSyncInAngleUpper

BOOL

Release of the attack point AP_lrSyncInAngleUpper.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrSyncInAngleUpper

LREAL

The parameter lrSyncInAngle (ramp angle) is used at the lower and upper reversal point.

AP_lrSyncInAngleUpper specifies an alternative ramp angle for the upper reversal point.

AP_xSyncOutAngleLower

BOOL

Release of the attack point AP_lrSyncOutAngleLower.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrSyncOutAngleLower

LREAL

The parameter lrSyncOutAngle (ramp angle) is used at the lower and upper reversal point.

AP_lrSyncOutAngleLower specifies an alternative ramp angle for the lower reversal point.

AP_xSyncOutAngleUpper

BOOL

Release of the attack point AP_lrSyncOutAngleUpper.

TRUE

The attack point overwrites the values at the access point in the signal flow.

AP_lrSyncOutAngleUpper

LREAL

The lrSyncOutAngle parameter (ramp angle) is used at the lower and upper reversal point.

AP_lrSyncOutAngleUpper specifies an alternative ramp angle for the upper reversal point.

AP_xExecuteReversingInstant

BOOL

Release of the attack point AP_ xExecuteReversingInstant.

A positive edge immediately changes the current laying direction.

FALSE↗TRUE

There is a direct change of direction of the traverse.

Attention:

The changeover is direct (hard)!

Incorrect use can lead to jerky movements of the traversing drive. If the traverser is currently in the reverse phase, this is also cancelled and the traverser immediately switches to the opposite direction.