Axis mode

The use of the motion axis within the application can be determined via the 27 subindex.

Axis mode (subindex 27)

Virtual axis 9400 HighLine i500 inverter i700 servo inverter i950 servo inverter Encoder

Axis mode

Selection list (Lenze setting printed in bold)

Info

0

simple

Minimum functional range and resource requirement in the control. Used for simple inverter applications (e.g. conveying belt).

The FB L_MC1P_BasicActuatingSpeed is available for this mode.

1

Standard

Intelligent control of a drive using the standard functions for positioning, cam, etc.

Read access Write access Can only be changed in "Disabled" state No download

UNSIGNED_16

The subindex 27 can be set on the Mechanical parameter tab.

"Standard" axis mode

In the standard mode of the Axis_Ref the setpoints are completely generated in the control system. The lower-level drive is cyclically supplied with new setpoints.

Functions for positioning, synchronism, cam and robotics are available.

Furthermore, automatic monitoring functions for following errors, limit positions etc. are available

"Simple" axis mode

In simple mode, the functional range of the motion axis is reduced to a minimum.

  • Evaluation of the drive communication status
  • Copying/Converting the transmitted process data of the drive
  • Infrastructure for the SDO communication with the drive

No cyclic monitoring functions for following errors, limit positions etc. are active.

The setpoints (ramp generation) are generated in the lower-level drive using the CiA402 velocity modes.

Note!

The objects of the velocity modes (0x6062 - vl TargetVelocity and 0x6044 - vl velocity actual value) have to be included in the mapping.

The FB L_MC1P_BasicActuatingSpeed is available for controlling the axis. The axis is exclusively controlled in the call context of the FB. This does not have to be called in the MotionTask.

When the simple axis mode is used, the selection of the available FBs is limited. The following FBs can be used:

  • L_MC1P_BasicActuatingSpeed
  • L_MC1P_BrakeInterface
  • L_MC1P_ChangeMachineData
  • L_MC1P_GetDigInputsFromDrive
  • L_MC1P_OpticalTracking
  • L_MC1P_ReadAxisStatusWords
  • L_MC1P_ReadMachineData
  • L_MC1P_ReinitNode
  • L_MC1P_SetQuickStopOption
  • MC_ReadParameter
  • MC_ReadBoolParameter
  • MC_WriteParameter
  • MC_WriteBoolParameter
  • L_DCO_ReadDriveParameter
  • L_DCO_ReadDriveParameterString
  • L_DCO_WriteDriveParameter
  • L_DCO_TransferDriveParameter